Catalogue CENTERLINE® Motor Control Centers
www.rockwellautomation.fr
print switch display
Page / 266
Make a request   
ROCKWELL AUTOMATION - 65726
/ 266
See other catalogues for ROCKWELL AUTOMATION
Text version of the page
Appendix
Fan(s) and Ventilation in Bulletins 2162Q, 2162R, 2163Q, and 2163R
System Voltage
NEMA Enclosure Type
Current Rating (Amperes)
Venting
Internal Circulating Fan(s)
Door Mounted Exhaust fan(s)
1, 1G
2.2-4.2
Yes
None
None
6.8-28
Yes
None
Yes
220-240V
2.2
None
None
None
12
4.2-22
None
Yes
None
30
Yes (filtered and gasketed)
None
Yes (filtered and gasketed)
1, 1G
1.3 - 5.0
Yes
None
Yes [1]
380-415V
8.7 - 28
Yes
None
Yes
12
1.3 - 22
None
Yes
None
28
Yes (filtered and gasketed)
None
Yes (filtered and gasketed)
Bulletins 2162Q and 2163Q
1.1 - 3.4
Yes
None
None
1, 1G
5
Yes
None
Yes [1]
480V
8.0 - 27
Yes
None
Yes
1.1 - 2.1
None
None
None
12
3.4 - 22
None
Yes
None
27
Yes (filtered and gasketed)
None
Yes (filtered and gasketed)
1, 1G
0.9-2.7
Yes
None
None
3.9-22
Yes
None
Yes ME
600V
0.9-1.7
None
None
None
12
2.7-17
None
Yes
None
22
Yes (filtered and gasketed)
None
Yes (filtered and gasketed)
1.3 - 5.0
Yes
None
None
1, 1G
8.7 - 30
Yes
None
Yes
37 - 56
Yes
None
Yes
380-415V
72 - 170
Yes
None
Yes
1.3 - 43
None
Yes
None
12
56 - 72
Yes (filtered and gasketed)
Yes
Yes (filtered and gasketed)
105 - 170
Yes (filtered and gasketed)
None
Yes (filtered and gasketed)
1, 1G
1.1 - 5.0
Yes
None
None
Bulletins
8.0 - 180
Yes
None
Yes
2162R and 2163R
1.1 - 34
None
Yes
None
480V
40 (without reactor)
None
Yes
None
12
40 (with reactor)
Yes (filtered and gasketed)
Yes
Yes (filtered and gasketed)
52 - 65
Yes (filtered and gasketed)
Yes
Yes (filtered and gasketed)
96 - 180
Yes (filtered and gasketed)
None
Yes (filtered and gasketed)
1, 1G
22 - 52
Yes
None
Yes
22 - 27
None
Yes
None
600
12
32 (without reactor)
None
Yes
None
32 (with reactor)
Yes (filtered and gasketed)
Yes
Yes (filtered and gasketed)
41 - 52
None
Yes
Yes (filtered and gasketed)
[1] If door mounted HIM and control station (pilot devices) are specified, the unit will be 2.0 space factors with vented door only for 1.3 - 5.0A at 380 - 415V, 5.0A at 480V and 3.9A at 600V
[2] If combination of -14GK61 and -14N2 or -14RLX and -14RXL is specified for the 3.9A @ 600V, the unit will be 2.0 space factors with vented door only.
245
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 251 p.251
page 252 p.252
page 253 p.253
page 254 p.254
page 255 p.255
page 256 p.256
page 257 p.257
page 258 p.258
page 259 p.259
page 260 p.260
page 261 p.261
page 262 p.262
page 263 p.263
page 264 p.264
page 265 p.265
page 266 p.266
Pages:
1-50
51-100
101-150
151-200
201-250
251-266
pdf-page pdf di En 2008-10-42-14