| | | | | | | | | | | | | | | | | | | | | | | | | | | Vertical Sections | | | | | | | | | | Catalog Number Explanation for Vertical Sections (SC) | | | | | | | | | | The NINTH POSITION consists of three (3) groups of three (3) letters each. • Each group of three (3) letters represents one (1) section. Select one (1) letter from each column to specify one (1) section. • Separate each section with a dash (e.g., 2100-AAT06-A1B-ABC-AAA-ANE). • If only one (1) section is selected, only one (1) group of three (3) letters is needed. • If two (2) sections are selected, two (2) groups of three (3) letters are needed, separated by a dash. • If three (3) sections are selected, three (3) groups of three (3) letters are needed, with each group of letters separated by a dash. Position | | | | | | | | | | continued from page 10-- - ABC - AAA - ANE | 11_Section Location and Type_ | | | | | | | | | | 1 | | | | | | | | | | | | | | | | | | | | | | | | | | | | 20" Wide Section | A_ | Standard Section | | T | For plug-in units | | | | | | | 6.0 Space Factor, Full mounting plate, 8.5" | | | | | | | A | 20" Wide Section | Z | working depth, without vertical bus and without vertical wireway | | X | No plug-in units | | | | | | | | | | 300A, 1.0 Space Factor | | | | | | | | | A | 600A, 1.0 Space Factor | | | | | | | | | B | 600A, 1.5 Space Factor | | | | | | B C | Incoming Line Lugs - Top Incoming Line Lugs - Bottom | | C D E F G H | 600A, Top - in horizontal wireway with pullbox 800A, 1.5 Space Factor 800A, 2.0 Space Factor 800A, Top, 1.0 Space Factor with pullbox 1200A, 2.0 Space Factor 1200A, Top - 1.0 Space Factor with pullbox | | | | | | | | | A" | 200A, R-Clips (Available as main only) | | | | | | | | | B | 200A, J-Clips (Available as main only) | | | | | | | | | C | 400A, R-Clips | | | | | | D E F G | Main FDS - Top, 600V Main FDS - Bottom, 600V Feeder FDS - Top, 600V Feeder FDS - Bottom, 600V | | D E F G H J K L | 400A, J-Clips 600A, R-Clips 600A, J-Clips 600A, Non-fused (Available as main only) 800A, L-Clips 800A, Non-fused (Available as main only) 1200A, L-Clips 1200A, L-Clips (Available as main only) | | | | | | | | | A" | 225A, JD (Available as main only) | | | | | | | | | B | 225A, HJD (Available as main only) | | | | | | | | | C | 225A, JDC (Available as main only) | | | | | | | | | D | 400A, kD | | | | A | 20" Wide Section | | | | E | 400A, HKD | | | | | | H | | | F G H J K L M N P Q R | 400A, KDC 600A, LD 600A, HLD 600A, LDC 800A, MDL 800A, MDLG (Available as main only) 800A, HMDL 800A, HMDLG (Available as main only) 1200A, ND 1200A, HND 1200A, NDG (Available as main only) | | | | | | J | Main Circuit Breaker - Bottom | | | | | | | K | Feeder Circuit Breaker - Top | | | | | | | L | Feeder Circuit Breaker - Bottom See Appendix for circuit breaker interrupting | | | | | | | | capacity | | S | 1200A, HNDG (Available as main only) | | | | | | | | | A | 3 kVA (1.5 kVA)[2],[3], 120V Sec. | | | | | | | | Single | B | 5 kVA (2.5 kVA)[2],[3], 120/240V Sec. | | | | | | | | Phase, | C | 7.5 kVA (3.7 kVA)[2],[3], 120/240V Sec. | | | | | | | | Bottom | D | 10 kVA (5 kVA)[2],[3], 120/240V Sec. | | | | | | M | Transformer - 480V Primary | Mounted | E | 15 kVA (7.5 kVA)[2],[3], 120/240V Sec. | | | | | | N | Transformer - 600V Primary | | F | 25 kVA (12.5 kVA)[2],[3], 120/240V Sec. | | | | | | | | Three | J | 10 kVA (5 kVA)[2],[3], 120/208V Sec. | | | | | | | | Phase, | K | 15 kVA (7.5 kVA)[2],[3], 120/208V Sec. | | | | | | | | Bottom | L | 25 kVA (12.5 kVA)[2],[3], 120/208V Sec. | | | | | | | | Mounted | M | 30 kVA (15 kVA)[2],[3], 120/208V Sec. | | | | TT | 25" Wide Section with 9" vertical wireway[1] | A | Standard Section | | A | For Plug-in Units | | | | T | Corner Section (supplied as a single shipping block only) | | No Modifications | | r | No Modifications | | | | | | | | | | | | | | | | | | | | | | [1] Shipping block maximum is two (2) sections. Cannot ship 20" and 25" wide sections in the same shipping block. [2] For NEMA Type 1 and NEMA Type 1 with gasket applications 3kVA and larger, a vented door is provided. [3] In NEMA Type 12 applications (non-ventilated 3kVA and larger industrial transformers), to maximize the transformer's life, it is recommended that the transformer not be loaded greater than 50% of its nameplate rating. | | | | | | | | | | 11 | | | | | | | | | | | | | | | | | | | | | | | | | | |
|