video corpo cad

Liquid cooling package LCP cooling systems
20Pages

{{requestButtons}}

Catalog excerpts

Liquid cooling package LCP cooling systems - 1

Faster - better - worldwide. O Liquid Cooling Package LCP Cooling Systems

Open the catalog to page 1
Liquid cooling package LCP cooling systems - 2

Faster - better - worldwide.

Open the catalog to page 2
Liquid cooling package LCP cooling systems - 3

Rittal – The System. The whole is more than the sum of its parts. The same is true of “Rittal – The System.” With this in mind, we have bundled our innovative enclosure, power distribution, climate control and IT infrastructure products together into a single system platform. Complemented by our extensive range of software tools and global service, we create unique added value for all industrial applications: Production plant, test equipment, facility management and data centres. Following our simple principle, “faster – better – worldwide”, we combine innovative products with efficient...

Open the catalog to page 3
Liquid cooling package LCP cooling systems - 5

IT cooling. System layout 1 IT chiller for redundant application LCP Inline flush CW, flush Air-cooled condenser

Open the catalog to page 5
Liquid cooling package LCP cooling systems - 6

Faster - better - worldwide.

Open the catalog to page 6
Liquid cooling package LCP cooling systems - 7

Easily achieve 50% energy savings! Thanks to intelligent control and flexible configuration with additional fans, energy savings of up to Ⅲ Identical volumetric flow with 3 – 6 fans Ⅲ Reduced noise levels with lower speeds Ⅲ Short amortisation period 50% are easily achieved with the new LCP generation, at the same volumetric flow and constant cooling output.

Open the catalog to page 7
Liquid cooling package LCP cooling systems - 8

Water-based cooling solution Rack cooling Power supply Data centres support corporate processes at ever-higher outputs. The packing density in computer systems is increasing, and processor capacity is growing. This leads to a continuous rise in heat development. Keep temperatures at a constant level with the highly efficient Rittal Liquid Cooling Packages (LCP). With optimised operating costs, our LCPs precisely and effortlessly dissipate heat losses of up to 24 kW per enclosure. Rack T3+ Redundant coolant supply Redundant power supply ◾ Redundant heat exchanger unit with two active water...

Open the catalog to page 8
Liquid cooling package LCP cooling systems - 9

Water-based cooling solution Rack cooling Suite cooling Data centres support corporate processes at ever-higher outputs. The packing density in computer systems is increasing, and processor capacity is growing. This leads to a continuous rise in heat development. Keep temperatures at a constant level with the highly efficient Rittal Liquid Cooling Packages (LCP). With optimised operating costs, our LCPs precisely and effortlessly dissipate heat losses of up to 55 kW per enclosure. Bayed suite cooling with the Rittal LCP Inline is extremely powerful, and the ideal climate control solution...

Open the catalog to page 9
Liquid cooling package LCP cooling systems - 10

Coolant-based cooling solution Rack cooling Whether rack-based cooling of one or two server racks, or suite cooling with aisle containment. LCP Rack DX or LCP Inline DX are the ideal cooling solution for small to medium-sized IT installations. In particular, the stand-alone IT application is easily cooled with these devices. Whereas in the past, cooling of stand-alone IT applications led to difficulties with conventional ceilings or air-conditioning units, the LCP DX devices support IT-compatible cooling. For retrofitting or exchanges, the existing coolant pipework can often be reused....

Open the catalog to page 10
Liquid cooling package LCP cooling systems - 11

Coolant-based cooling solution Suite cooling Whether rack-based cooling of one or two server racks, or suite cooling with aisle containment, LCP Rack DX and LCP Inline DX are the ideal cooling solution for small to medium-sized IT installations. In particular, the stand-alone IT application is easily cooled with these devices. Whereas in the past, cooling of stand-alone IT applications led to difficulties with conventional ceilings or air-conditioning units, the LCP DX devices allow IT-compatible cooling. For retrofitting or exchanges, the existing coolant pipework can often be reused....

Open the catalog to page 11
Liquid cooling package LCP cooling systems - 12

Water-based fanless cooling solution Rack cooling The fans in the IT equipment independently guide the warm air over the high-capacity heat exchanger. The entire data centre functions as a cold aisle, and there is homogeneous temperature distribution. The LCP Passive creates a very large, effective heat exchanger surface area in the data centre which facilitates high water inlet temperatures and a high proportion of free cooling. High cooling output of 20 kW in a minimal space Easily exchanged for the standard rear door of the server enclosure Retrofitting is not a problem A door opening...

Open the catalog to page 12
Liquid cooling package LCP cooling systems - 13

LCP – Liquid Cooling Package CW Accessories from page 48 Benefits: ◾ Maximum energy efficiency thanks to EC fan technology and IT-based control ◾ Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans ◾ Optimum adaptability thanks to dynamic, continuous control of the cold water volume flow ◾ Using high water inlet temperatures increases the proportion of indirect free cooling, which in turn reduces operating costs ◾ Targeted cooling output thanks to modular box-type plug-in fan units ◾ Box-type plug-in fan units configurable as n+1 redundancy ◾...

Open the catalog to page 13
Liquid cooling package LCP cooling systems - 14

LCP – Liquid Cooling Package CW Accessories from page 48 Benefits: ◾ Maximum energy efficiency thanks to EC fan technology and IT-based control ◾ Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans ◾ Optimum adaptability thanks to dynamic, continuous control of the cold water volume flow ◾ Using high water inlet temperatures increases the proportion of indirect free cooling, which in turn reduces operating costs ◾ Targeted cooling output thanks to modular box-type plug-in fan units ◾ Box-type plug-in fan units configurable as n+1 redundancy ◾...

Open the catalog to page 14
Liquid cooling package LCP cooling systems - 15

LCP – Liquid Cooling Package CW Accessories from page 48 Benefits: ◾ Error-tolerant, efficient cooling of server racks with high thermal loads ◾ Fully redundant – Two active cooling circuits and two switchable power circuits ensure optimum fail-safeness ◾ The built-in controllers are capable of adapting all device parameters automatically to preserve the required climate conditions ◾ A separate decentralised intelligence which automatically recognises emergency situations and responds appropriately with the “auto-load balancing” and “auto-recovery” functions ◾ Interfaces which facilitate...

Open the catalog to page 15

All RITTAL catalogs and technical brochures

  1. VX25

    220 Pages

Archived catalogs

  1. TS IT RACK

    68 Pages

  2. RiLine60

    120 Pages

  3. Ri4Power

    148 Pages

  4. Catalogue 32

    1348 Pages