"Shtrikh-2", 3D Laser scanning system
With reference to the work diagram ("Sequence Chart of Control Signals" Leadshine page 8 or "Input signal timing diagram" YAKO page1), it is necessary to use interfacing method for a machine with direct control of stepping driver, see 8.1.1., and set
switches in the optical isolation unit according to the following scheme:
26
Figure 16 Position of switches in the optical isolation unit for stepping drivers Leadshine
M542/YAKO YKB2608 and similar
Two methods of interfacing or connection are possible: with the use of optical isolation unit or without using it.
First method (with optical isolation unit):
find “ground” on the machine with reference to which the signals PUL+/PUL-,
DIR+/DIR- (DR, PU) work. The ground terminal is normally located on power
supply or on a separate board with marked with "СОМ".
connect this ground to the AGND input of the optical isolation unit.
connect
signals
from
the
X
co-ordinate
driver:
PUL- (PU) to the xSTEP+ input of the optical isolation unit;
DIR- (DR) to the xDIR+ input of the optical isolation unit.
Important: If the ground for AGND is chosen incorrectly, the system will not work. The
program will return error: Error! Data file empty or Error! Check gaging speed.
Important: If the ground for AGND is chosen incorrectly, the system will not
work. The program will return error: Error! Data file empty or Error! Check
movement speed
Also, check signal levels to which the optical isolation unit is connected. If
the signal level is higher than +7V, the optical isolation unit will fail to function.
Shtrikh-2 [Revision 2.3] 19 March 2011
|
|