8
Emergency stop and safety gate monitoring relays
SAFE 2 / SAFE 2.1 SAFE S.6
Emergency stop Emergency stop
and safety gate monitoring relay and safety gate monitoring relay
CE, TÜV, UL, C-UL CE, TÜV, UL, C-UL
2 normally open safety 2 normally open safety
LED indicators for status and supply diagnostic LED indicators for status and supply diagnostic
Selectable opposite polarity between channels
With (SAFE 2) and without (SAFE 2.1) start control
Power, channel 1 and channel 2 Power, channel 1 and channel 2
24 V AC / DC (electronic fuse) 24 V AC / DC (without galvanic disconnection, but with a fuse F1)
24 V DC (without galvanic disconnection, but with an electronic fuse)
24, 48, 110-127, 230 V AC (with galvanic disconnection/transformer)
ca. 2,5 VA / 2,5 W ca. 3 VA
< 50 ms / < 30 ms < 150 ms / < 30 ms
6 A, 250 V AC, 24 V DC 6 A, 250 V AC, 24 V DC
6 mA 100 mA (*)
Simultaneous protective door contacts : ca. 65 ms
-25°C to + 55°C -25°C to + 55°C
1500 VA (resistive load) 1380 VA (resistive load)
6,3 A quick acting or 4 A time lag 6 A quick acting or 4 A time lag
A supply voltage must be applied to terminals A1 and A2. Power LED illuminates
and 24V DC is available at terminal S11. Terminals S12 and S22 must be
connected according to the application example selected to meet the application
requirements. To start the unit terminals S33 and S34 must be bridged with a
normally open contact. The unit works if you close this contact. At this time the
contacts 13-14 and 23-24 are closed. The LEDs channel 1 and channel 2
illuminate. In series to this start button an external contactor can be controlled.
S34 S33 S11 S12 S21 S22
Not-Halt
E-Stop
Start
A supply voltage must be applied at terminals A1 and A2 in order to operate the
device. If this is done there is a voltage of 24V DC at terminal T11. Terminals T12
and T22 must be wired as shown in the application examples. To start the unit
terminal T11 must be bridged with terminal T34 by means of a closing contact or
terminal T34 must receive a 24V DC impulse (short time bridging of the
connection terminals T11-T34). If this is down contacts 13-14 and 23-24 close. The
LEDs channel 1 and channel 2 illuminate. In series with the start button and
terminals T11 / T34 the function of an external contactor can be monitored.
(*) We offer all devices which have a contact capacity of min. 100mA at 24V DC
with hard gold-plated contacts. In this way you get a contact capacity of 4mA.
T34 T33 T11 T12 T22 T44 /
PE
Not-Halt
Start E-Stop
Überwachungslogik /
control logic
~ ~
S21
~~
+
=
K1
A1
(+)
elektr.
Sicherung /
electronic
fuse
A2
(-) S11 S12
14
K2
K2
24
K1
S22 S33 S34 13 23
~~
- +
=
~ ~
A1 (+) A2 (-) T11 T34 T12 T22 T33 13 23
K3
K2
K1
F1 T1
K1 K3 K2
T44/PE 14 24
EN ISO 13849-1: PLe, Cat.4
MTTFd: 69 years / high, DC: 99% / high,
CCF: achieved
EN ISO 13849-1: PLd/e, Cat.3 /4
MTTFd: 74,15 years / high, DC: Cat. 3: 90% / medium, Cat. 4: 99% / high
CCF: achieved
|
|