Overview: The HYDROSTATIC LEVEL METER LEVEL36 XKY by Riels Instruments is designed for use in sewage lift station environments. It features a wide sensing diaphragm and compact size, utilizing a Kynar® diaphragm for durability and ease of installation. The device employs piezoresistive silicon measurement technology and microprocessor-based signal conditioning for accuracy and reliability.
Specifications: The LEVEL36 XKY supports standard 2-wire (4–20 mA) or 3-wire (0–10 V) output transmitters and includes an RS485 interface for analog output scaling. It is suspended by a Hytrel®-jacketed cable, with optional lightning protection for areas prone to transient damage.
Product Benefits: Key benefits include a non-fouling diaphragm design, chemical-resistant housing (AISI 316L), digital RS485 interface, rangeable analog output, and enhanced reliability in lightning-prone regions.
Pressure Ranges: The standard pressure ranges are 1, 2, and 3 bar, with overpressure capabilities of 3, 5, and 10 bar respectively. Accuracy is maintained at +/- 5 mbar within 0 to 50 °C.
Output and Interface: The device offers various output options including 4–20 mA, 0–10 V, and RS485. It supports a supply voltage range of 6–28 V, with current consumption varying based on configuration. Enhanced lightning protection is available, increasing supply voltage by 1 V and providing insulation up to 200 V.
Communication and Options: The LEVEL36 XKY supports RIELS-BUS and MODBUS RTU communication protocols at 9600 and 115200 baud rates. It includes options for different housing materials and enhanced lightning protection.
Additional Features: The device is equipped with a Hytrel® jacketed cable, IP68 protection, and operates within a compensated temperature range of 0–50 °C. It also features a power-on time of 600 ms and EMC compliance with EN 61326-2-3 standards.
See more

Catalog excerpts

36XKY Level Transmitters for sewage applications Riels®Instruments-1

HYDROSTATIC LEVEL METER Level Transmitters with Kynar® for sewage applications / non-fouling Specifically designed for extended service in sewage lift station environments, the 36XKY by RIELS® features a relatively wide sensing diaphragm yet small overall size. The 36XKY incorporates a monolithic diaphragm formed from Kynar®, which combines the non-stick quality of Teflon with superior toughness and abrasion resistance that simplify installation and eliminate the need for bulky and expensive protective cages. Tutti i dati ed i contenuti di questa scheda sono di proprietà esclusiva di Riels Instruments The 36XKY utilizes proven piezoresistive silicon measurement technology combined with Riels's state-of-the-art, microprocessor-based signal conditioning circuitry to provide outstanding accuracy and reliability over a wide compensated temperature range. It is perfectly suited for pump control applications that require standard 2-wire (4…20 mA current loop) or 3-wire (0…10 V) output transmitters. The RS485 interface allows users to scale the analog output to any desired range within the standard pressure range. The 36XKY is typically suspended into the liquid by a standard Hytrel®-jacketed cable that is both self-supporting and vented. Optional: Riels's enhanced lightning protection makes this transmitter ideal for installation in areas prone to chronic damage due to transients caused by lightning. Using the Keller CCS30 software and appropriate adapter cable, the user can scale the analog output of the 36XKY, display and record pressure and temperature readings, and access a variety of other available functions. All of the available functions are defined in the Series 30 Communications Protocol. The CCS30 and Series 30 Communications Protocol are available free of charge from the company website. Product Benefits: - Non-fouling diaphragm design - Housing resist chemical attack (AISI 316L) - Digital interface RS485 - Rangeable analog output - Mathematically compensated - Increased reliability in lightning-prone regions Specifications STANDARD PRESSURE RANGES (FS) AND OVERPRESSURE IN BAR PR-36 XKY Overpressure All intermidiate ranges for the analog output are realized by downscaling from the next higher standard range. The accuracy is calculated from the standard range. Ranges below 1 bar are realized with the 1 bar range. Accuracy for these ranges is +/- 5 mbar (0 .. 50 °C).

 Open the catalog to page 1
36XKY Level Transmitters for sewage applications Riels®Instruments-2

Analog 2-wire Output Digital Interface Supply (VDC) 2) Current Consumption 3) Accuracy 4) Total Error Band 5) 0…50 °C 1) During RS485 communication the analog signal will be influenced. 2) With lightning protection: Minimum supply voltage increase by 1 V 3) With no load on the analog output and no RS485 communication. For RS485 current consumption see details below. 4) Includes linearity (BFSL), hysteresis and repeatability 5) Includes accuracy as well as temperature coefficients of zero and span tolerance < (U–8 V) / 0,025 A (2 wire) > 5’000 Ω (3 wire) 0,002 %FS Cable: Hytrel®, jacketed, integrated...

 Open the catalog to page 2

All Riels Instruments catalogs and technical brochures

  1. DEEPER

    1  Page

  2. miniELCOR

    4  Pages

  3. EL-USB-4

    5  Pages

  4. EE33

    6  Pages

  5. EE300Ex-HT

    6  Pages

  6. AVFM 5.0

    3  Pages

  7. EE 75

    5  Pages

  8. EE776

    6  Pages

  9. EE771/2

    6  Pages

  10. TRICOR

    15  Pages

  11. FFU

    7  Pages

  12. RIF600W

    4  Pages

  13. RIF180

    3  Pages

  14. MC 505

    1  Page

  15. HM-R

    3  Pages

  16. HD408T

    2  Pages

  17. RIB300

    3  Pages

  18. 23/25 ED

    2  Pages

  19. RIB180

    4  Pages

  20. FLD48

    2  Pages

  21. CLM-36

    6  Pages

  22. DLM-35

    2  Pages

  23. DLS-27

    7  Pages

  24. CLS-23

    5  Pages

  25. PFG05/ATFHV60

    2  Pages

  26. LFP

    2  Pages

  27. GRLM70

    9  Pages

  28. RIL600

    5  Pages

  29. LITTLE EX

    1  Page

  30. MATIC/V/MC

    2  Pages

  31. DCX22

    2  Pages

  32. MN03

    1  Page

  33. LEO RECORD

    2  Pages

  34. EV220B

    13  Pages

  35. WWG

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.