You may also be interested in
Pressure regulator, Flow regulator, Pneumatic pressure regulator, Pneumatic regulator, Proportional pressure regulator
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:5.95pt "Arial", sans-serif; }
.font1 { font:9.00pt "Arial", sans-serif; }
.font2 { font:14.00pt "Arial", sans-serif; }
.font3 { font:29.00pt "Arial", sans-serif; }
Type RP500
Technical data
Voltage..........................24 VDC ±10 %
Power consumption, electrical...........4.5 W max.
Connection, electrical.................terminal- or customer-sp. connector
Pressure supply.....................25 bar max.
Pressure range ..................... 0 to 24 bar
Medium..........................compressed air, oiled, on-oiled,
neutral gasses, filtered 50 pm
Air consumption ....................no permanent air consumption
Flow............................4100 l/min at an input pressure of 6 bar
Connection thread...................G 1/2" (1 + 2)
Connection thread, manometer..........G 1/4" (2)
Ingress protection...................IP 67
Operating temperature range ...........-5 to +50 °C
Hysteresis ........................< 0.2 % of the corresponding range
Repeatability ......................< 0.2 % of the corresponding range
Weight ..........................1.2 kg
Type key
Sample order
RP500 with a pressure range of 0 to 10 bar, control signal 0-10 V, analog circuit board, Fail Safe = pressureless, with external sensor 4-20mA Order code: RP500/0-10/1/A/2/E3
Pressure range
Control range 0 to 24 bar
Précision pressure regulator
1/2" connection
This pressure controller serves to control high flow rates of up to 250 m3/h at 6 bar. The large cross-section of the secondary vent also ensures fast
evacuation or adaptation of the secondary pressure, also for large volumes. A sensor in the outlet section monitors the discharge pressure which is constantly compared with the set value. Deviations are adjusted quickly and accurately.
Set value input (Control signal)
1 2 3 P
M C
0-10 V 0-20 mA 4-20 mA
Profibus-DP
Modbus CanBus
I Interbus S D Device-Net R RS232 S RS485
T set-point potentiometer on the housing (free of potential on request, other analog areas on request) Version
A Analog circuit board -
M Digital microprocessor circuit board Fail Safe (in case of power failure)
1 pressure maintenance
2 pressureless -
Options
N no option E actual value input E1 = 0-10 V, E2 = 0-20 mA, E3 = 4-20 mA G potential isolation in set value input S soft start after EMERGENCY OFF (3 secs.) Actual value output
The response signal corresponds to the range of the control signal. Other ranges on request.