Al
apply innovation"
Accuracy
Nominal external diameter
Graduation error (arc second)
System error (arc second) for 20 urn systems
System error (arc second) for 40 um systems
52 mm
± 4.0
± 5.6
± 6.3
57 mm
± 3.6
± 5.1
± 5.8
75 mm
± 2.8
± 3.9
± 4.4
100 mm
± 2.1
± 2.9
± 3.3
103 mm
± 2.0
± 2.8
± 3.2
104 mm
± 2.0
± 2.8
± 3.2
115 mm
± 1.8
± 2.5
± 2.9
150 mm
± 1.4
± 1.9
± 2.2
200 mm
± 1.0
± 1.4
± 1.7
206 mm
± 1.0
± 1.4
± 1.6
209 mm
± 1.0
± 1.4
± 1.6
229 mm
± 0.9
± 1.3
± 1.4
255 mm
± 0.8
± 1.1
± 1.3
300 mm
± 0.7
± 1.0
± 1.1
350 mm
± 0.6
± 0.8
± 0.9
413 mm
± 0.5
± 0.7
± 0.8
417 mm
± 0.5
± 0.7
± 0.8
550 mm
± 0.4
± 0.5
± 0.6
Graduation error is the maximum difference between the angle measured by a single readhead and the true rotation of the encoder as graduated. Application disturbances such as eccentricity are not included.
System error is graduation error plus SDE.
Effects such as eccentricity influence installed performance; for application advice please contact your local representative.
,o' wo,,dwide contact detai,s! please Visit oUI
main website at www renishaw com/contact
RENISHAW® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc.
© Renishaw plc 2002-2008 Issued 0108 Renishaw reserves the right to change specifications without notice
L-9517-9128-04

pageCatalog pdf di En 2012-05-22-31