MR-GU32P-TR2

monitoring relays 49

Dimensions Connections diagrams
Input 230 Vwith TR2 24 V AC without fault latchInput 230 Vwith TR2 230 V AC with fault latch Input 230 V with TR2 400 V AC without fault latch Mounting, mechanical design Relays MR-GU32P-TR2 are designed for direct mounting on 35 mm DIN rail mount, EN 50022. Mounting position: any.Self-extinguishing plastic housing, IP 40. Shockproof terminal connection according to VBG 4 (PZ1 required), IP 20.Maximum screw torgue: 1,0 Nm. Terminal capacity: 1 x 0,5 do 2,5 mm
2 with/without multicore cable end, 1 x 4 mm
2 withoutmulticore cable end, 2 x 0,5 do 1,5 mm
2 with/without multicore cable end, 2 x 2,5 mm
2 flexible without multicore cable end. Functions
For all functions the LED's MIN and MAX areflashing alternating, when the minimum value for the measured voltage was chosen to be greater than the maximum value. If a failure already exists, when the device is activated, the output relay R remains in off-position and the LED forthe corresponding threshold is illuminated. UNDER, UNDER+LATCH - undervoltagemonitoring, undervoltage monitoring withfault latch OVER, OVER+LATCH - overvoltagemonitoring, overvoltage monitoring with fault latch The output relay R switchs into on-position (yellowLED illuminated) when the measured voltage of all the phases exceeds the value adjusted at the MIN-regulator. When the measured voltage of one of the phases exceeds the value adjusted at the MAX-regulator, the set interval of the tripping delay(Delay) begins (red LED MAX flashes). After theinterval has expired (red LED MAX illuminated), theoutput relay R switches into off-position (yellow LED not illuminated). The output relay R again switchs into on-position (yellow LED illuminated) when the measured voltage of all the phases falls below the value adjusted at the MAX-regulator (red LED MAX not illuminated). When the measured voltage of one of the phases falls below the value adjusted at the MIN-regulator, the set intervalof the tripping delay (Delay) begins again (red LEDMIN flashes). After the interval has expired (redLED MIN illuminated), the output relay R switchesinto off-position (yellow LED not illuminated).If the fault latch is activated (WIN+LATCH)and the measured voltage of one of the phases remains below the MIN-value longer than the set interval of the tripping delay, the output relay Rremains in the off-position even if the measuredvoltage of all the phases exceeds the value adjusted at the MIN-regulator. If the measured voltage of one of the phases remains above the MAX-value longer than the set interval of thetripping delay, the output relay R remains in theoff-position even if the measured voltage of all the phases falls below the value adjusted at the MAX- regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relay R switches into on-position and a newmeasuring cycle begins with the set interval ofthe start-up suppression (START). When the measured voltage of one of the phasesfalls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (Delay) begins (red LED MIN flashes). After the interval has expired (red LED MIN illuminated), the output relay R switches into off-position (yellow LED notilluminated). The output relay R again switchs intoon-position (yellow LED illuminated), when themeasured voltage of all the phases exceeds thevalue adjusted at the MAX-regulator. If the fault latch is activated (UNDER+LATCH) and the measured voltage of one of the phases remains below the MIN-value longer than the set interval of the tripping delay, the output relay Rremains in the off-position even if the measuredvoltage of all the phases exceeds the value adjusted at the MAX-regulator. After resettingthe failure (interrupting and re-applying the supplyvoltage), the output relay R switches into on-positionand a new measuring cycle begins with the set interval of the start-up suppression (START). When the measured voltage of one of the phasesexceeds the value adjusted at the MAX-regulator, the set interval of the tripping delay (Delay) begins (red LED MAX flashes). After the interval has expired (red LED MAX illuminated), the output relayR switches into off-position (yellow LED notilluminated). The output relay R again switchs intoon-position (yellow LED illuminated), when the measured voltage of all the phases falls below the value adjusted at the MIN-regulator (red LED MAX not illuminated). If the fault latch is activated (OVER+LATCH) and the measured voltage of one of the phases remains above the MAX-value longer than the set interval of the tripping delay, the output relay Rremains in the off-position even if the measuredvoltage of all the phases falls below the valueadjusted at the MIN-regulator. After resettingthe failure (interrupting and re-applying the supply voltage), the output relay R switchs into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). - output relay R WIN, WIN+LATCH - voltage monitoringin windowfunction between MIN and MAXvalues, voltage monitoring in windowfunction between MIN and MAX values with fault latch - supply voltage; U Dział Marketingu Tel./Fax +48 68 47 90 830 • Wsparcie Techniczne Tel. +48 68 47 90 820 www.relpol.com.pl

pageCatalog pdf di En 2012-05-22-31