MR-GU1M2P-TR2

monitoring relays 47

Dimensions Connections diagrams
Input 30 Vwith TR2 24 V AC with fault latchInput 60 Vwith TR2 230 V AC with fault latch Input 300 V with TR2 400 V AC without fault latch Mounting, mechanical design Relays MR-GU1M2P-TR2 are designed for direct mounting on 35 mm DIN rail mount, EN 50022. Mounting position: any.Self-extinguishing plastic housing, IP 40. Shockproof terminal connection according to VBG 4 (PZ1 required), IP 20.Maximum screw torgue: 1,0 Nm. Terminal capacity: 1 x 0,5 do 2,5 mm
2 with/without multicore cable end, 1 x 4 mm
2 withoutmulticore cable end, 2 x 0,5 do 1,5 mm
2 with/without multicore cable end, 2 x 2,5 mm
2 flexible without multicore cable end. Functions
When the supply voltage U is applied, the outputrelay R switches into on-position (yellow LED illuminated) and the set interval of the start-upsuppression (START) begins (green LED U flashes).Changes of the measured voltage during thisperiod do not affect the state of the output relay R. After the interval has expired the green LEDis illuminated steadily. For all the functionsthe LEDs MIN and MAX are flashing alternating,when the minimum value for the measured voltagewas chosen to be greater than the maximum value. UNDER, UNDER+LATCH - undervoltagemonitoring, undervoltage monitoring withfault latch When the measured voltage exceeds the valueadjusted at the MAX-regulator, the set intervalof the tripping delay (Delay) begins (red LED MAX flashes). After the interval has expired (red LEDMAX illuminated), the output relay R switchesinto off-position (yellow LED not illuminated).The output relay R again switchs into on-position(yellow LED illuminated) when the measured voltage falls below the value adjusted at the MAX-regulator (red LED MAX not illuminated). When themeasured voltage falls below the value adjustedat the MIN-regulator, the set interval of the tripping delay (Delay) begins again (red LED MIN flashes). After the interval has expired (red LED MIN illuminated), the output relay R switches intooff-position (yellow LED not illuminated).If the fault latch is activated (WIN+LATCH) and the measured voltage remains below the MIN- value longer than the set interval of the trippingdelay, the output relay R remains in the off-positioneven if the measured voltage exceeds the valueadjusted at the MIN-regulator. If the measuredvoltage remains above the MAX-value longer than the set interval of the tripping delay, the outputrelay R remains in the off-position even if themeasured voltage falls below the value adjustedat the MAX-regulator. After resetting the failure(interrupting and re-applying the supply voltage),the output relay R switches into on-position anda new measuring cycle begins with the set interval of the start-up suppression (START). OVER, OVER+LATCH - overvoltagemonitoring, overvoltage monitoring with fault latch When the measured voltage falls below the valueadjusted at the MIN-regulator, the set intervalof the tripping delay (Delay) begins (red LED MINflashes). After the interval has expired (red LEDMIN illuminated), the output relay R switches into off-position (yellow LED not illuminated).The output relay R again switchs into on-position(yellow LED illuminated), when the measured voltage exceeds the value adjusted at the MAX-regulator.If the fault latch is activated (UNDER+LATCH)and the measured voltage remains below the MIN- value longer than the set interval of the tripping delay, the output relay R remains in the off-positioneven if the measured voltage exceeds the valueadjusted at the MAX-regulator. After resettingthe failure (interrupting and re-applying the supply voltage), the output relay R switches into on-position and a new measuring cycle begins with the setinterval of the start-up suppression (START). When the measured voltage exceeds the valueadjusted at the MAX-regulator, the set interval of the tripping delay (Delay) begins (red LED MAXflashes). After the interval has expired (red LEDMAX illuminated), the output relay R switchesinto off-position (yellow LED not illuminated). The output relay R again switchs into on-position (yellow LED illuminated), when the measuredvoltage falls below the value adjusted at the MIN-regulator (red LED MAX not illuminated).If the fault latch is activated (OVER+LATCH) and the measured voltage remains above the MAX- value longer than the set interval of the trippingdelay, the output relay R remains in the off-positioneven if the measured voltage falls below the valueadjusted at the MIN-regulator. After resettingthe failure (interrupting and re-applying the supply voltage), the output relay R again switchs intoon-position and a new measuring cycle begins with the set interval of the start-up suppression (START). - output relay R WIN, WIN+LATCH - voltage monitoringin windowfunction between MIN and MAXvalues, voltage monitoring in windowfunction between MIN and MAX values with fault latch - supply voltage; U Dział Marketingu Tel./Fax +48 68 47 90 830 • Wsparcie Techniczne Tel. +48 68 47 90 820 www.relpol.com.pl

pageCatalog pdf di En 2012-05-22-31