You may also be interested in
Data acquisition system, Digital display, Rotary encoder, Interface, Resistive temperature detector
Text version of the page
3
GENERAL METER SPECIFICATIONS
1. DISPLAY: 6 digit, 0.56" (14.2 mm) red sunlight readable or standard green
LED
2. POWER:
AC Versions:
AC Power: 85 to 250 VAC, 50/60 Hz, 18 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working)
DC Versions:
DC Power: 11 to 36 VDC, 14 W
(derate operating temperature to 40° C if operating <15 VDC and three
plug-in option cards are installed)
AC Power: 24 VAC, ± 10%, 50/60 Hz, 15 VA
Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working).
3. SENSOR POWER: 12 VDC, ±10%, 100 mA max. Short circuit protected
4. KEYPAD: 3 programmable function keys, 5 keys total
5. USER INPUTS: Three programmable user inputs
Max. Continuous Input: 30 VDC
Isolation To Sensor Input Commons: Not isolated
Logic State: Jumper selectable for sink/source logic
Response Time: 6 msec. typical; function dependent. Certain resets, stores
and inhibits respond within 25 ìsec if an edge occurs with the associated
counter or within 6 msec if no count edge occurs with the associated
counter. These functions include ƒ³ƒäƒâƒÃƒäƒ¼, ƒ³ƒäƒâƒÃƒäƒµ, ƒ¸ƒ¼ƒâƒÃƒäƒ¼, ƒ¸ƒ¼ƒâƒÃƒäƒµ,
ƒ¹ƒ¾ƒ¸ƒ¹ƒÒƒä, ƒÃƒäƒ¿ƒâƒµ, and ƒÀƒâƒ¾ƒâƒÃƒä. Once activated, all functions are latched for
50 msec min. to 100 msec max. After that period, another edge/level may
be recognized.
6. MEMORY: Nonvolatile E2PROM retains all programmable parameters and
display values.
7. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File #E179259, UL61010A-1, CSA C22.2
No. 1010-1
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
UL Listed, File #E137808, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report #04ME11209-20041018
Issued by Underwriters Laboratories, Inc.
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
IP20 Enclosure rating (Rear of unit), IEC 529
ELECTROMAGNETIC COMPATIBILITY
Note:
Refer to EMC Installation Guidelines section of the bulletin for additional
information.
8. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50°C (0 to 45°C with all three plug-in
cards installed)
Storage Temperature Range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. relative humidity noncondensing
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
direction for 1.5 hours, 2 g’s.
Shock According to IEC 68-2-27: Operational 25 g's (10 g's relay), 11 msec in
3 directions.
Altitude: Up to 2000 meters
9. CONNECTIONS: High compression cage-clamp terminal block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
10. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use.
IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece
bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and
mounting clip included.
11. WEIGHT: 10.1 oz. (286 g)
Inactive VIN > 3.6 VDC VIN 3.6 VDC
SINKING INPUTS
5.1 KĂ pull-up to +12 V
SOURCING INPUTS
INPUT STATE 5.1 KĂ pull-down
Power mains class A
RF interference EN 55011 Enclosure class A
Emissions to EN 50081-2
150 KHz - 80 MHz
RF conducted interference EN 61000-4-6 Level 3; 10 V/rms
Level 3; 2 Kv power
Fast transients (burst) EN 61000-4-4 Level 4; 2 Kv I/O
80 MHz - 1 GHz
Electromagnetic RF fields EN 61000-4-3 Level 3; 10 V/m
Level 3; 8 Kv air
Electrostatic discharge EN 61000-4-2 Level 2; 4 Kv contact
200 Hz, 50% duty cycle
900 MHz „b5 MHz
Immunity to EN 50082-2
Simulation of cordless telephones ENV 50204 Level 3; 10 V/m
|
|