| | Active Zone [mm] | 10...25, related to probe tip | - | 10...25, related to the probe tip + 1 x type specific X2 | |
| | | |
| | Probe | KFS-5-1-"L"-15-Y55 | | |
| | Evaluation unit NPN antivalent | KFA-5-1-N-A-Y50 | | |
| | Evaluation unit PNP antivalent | KFA-5-1-P-A-Y50 | | |
| | Compact filling level probe NPN NO | KFX-5-2-"L"-15/X2-N-S-VA-1" | |
| | Compact filling level probe NPN NC | KFX-5-2-"L"-15/X2-N-Ö-VA-1" | |
| | Compact filling level probe PNP NO | KFX-5-2-"L"-15/X2-P-S-VA-1" | |
| | Compact filling level probe PNP NC | KFX-5-2-"L"-15/X2-P-Ö-VA-1" | |
| | Operating voltage (UB) | | 18...36VDC | 18...36VDC | |
| | Output current max. (Ie) | - | 2 x 250 mA | 2 x 250 mA | |
| | No-load current (I0) | - | typ. 50 mA | typ. 50 mA | |
| | Frequency of operating cycles max. | - | 4 Hz | 4 Hz | |
| | Permitted ambient temperature | - | -25...+55°C | -25...+55°C | |
| | Permitted ambient temperature (for active zone) | -70...+250°C | - | -25...+100°C | |
| | LED-Display | - | yes | yes | |
| | Protective circuit | - | yes | yes | |
| | Degree of protection IEC 529 | IP 67 | IP 65 | IP 67 | |
| | Connection | 2 m coax-cable with coax-connector | 2 m cable | Clamp terminal within the connection head | |
| | Housing material | - | PA/PPO | VA No. 1.4571 | |
| | Active zone | GFK | - | GFK | |
| | Pressure | - | - | 25 bar | |
| | | | | | |