| | | Series: ™LeVeL 2 Limit value switching points | | |
| | | |
| | | • For connection to the capacitive amplifier KFA-5-3-... • Housing material: GFK, 16 mm 0 • Connection head and process connection aluminium die cast • Process connection 1" • Probe length max. 2000 mm | | |
| | | |
| | | Certificate: | | |
| | | |
| | | Technical data Active Zone [mm] | | |
| | | 10... 25, related to probe tip + 1 x type specific X2 | | |
| | | |
| | | |
| | | Type KFS-5-2-"L"-15/X2-AL-1" | | |
| | | |
| | | | | | | | | | Connection diagram | see below | | | | Permitted ambient temperature | -25...+100°C | | | | Permitted ambient temperature (for active zone) | -25...+150°C | | | | Degree of protection IEC 529 (Housing) | IP 67 | | | | Degree of protection IEC 529 (screwing*cable connection) | IP 54 | | | | Connection to the evaluation unit KFA-5-3-... | SMB-sockets within the connection head | | | | Housing material | AL | | | | Active zone | GFK | | | | | | | | | |
| | | |
| | | Pressure 6 bar | | |
| | | |
| | | Connection cable (with Y75/Y75 SMB industrial connector) is not delivered with the probe Order specifications: see page 50. | | |
| | | |
| | | * The degree of protection may be increased by means of special measures at mounting (e. g. injection of silicone mixture). Other housing materials for the active zone (probe), like PE, PVDF or PEEK on request. Please determine the position of the second switching point "X2" when ordering. | | |
| | | o o 55 o ai o o o CD to o o o 0} !q cn CO o "co o 'o 03 q. CO | | |
| | | |
| | | Connection sockets withir connection. | | |
| | | 115 | | |
| | | |
| | | |
| | | |
| | | 26 RECHNER Industrie-Elektronik GmbH • Gaußstraße 8-10 • D-68623 Lamperthäm • Tel. +49 (0) 62 06 50 07-0 • Fax +49 (0) 62 06 50 07-20 • emäl info@rechner-sensors.de • www.rechner-sensors.de | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |