| | | Inductive Sensors Series 30 - NAMUR | | |
| | | |
| | | Housing M30 x 1.5 • <g> II 2 G EEx ia IIC T1-T6 • ^)ll 1 DIP67T101°C • For use in areas where there is a risk of explosion • Housing material: brass • Flush mountable • Sensing distance Sn = 10 mm | | |
| | | Certificate: DMT 03 ATEX E 048 | | |
| | | |
| | | |
| | | Technical data | | |
| | | |
| | | | | | | | | | | Operating distance Sn [mm], flush mounting | 10, yes | | | | | | | | Electrical version | 2-wire DC | 3-wire DC | | | | Output | NAMUR DIN 60947-5-6 | | | | Type | IAS-30-A14-N | IAS-30-A14-N-StEx | | | | Application/Marking | Ex II 2 G EEx ia IIC T1-T6 | | | | Ex II 1 D IP 67T101°C | | | | Art.-No. | 300 500 | IA 0095 | | | | Connection diagram No. | 1 | 2 | | | | | | | | | | |
| | | |
| | | Operating voltage (UB) Output current active surface free Output current active surface covered Self-inductance (L) Self-capacitance (C) Permitted residual ripple max. Frequency of operating cycles max. Permitted ambient temperature LED-display | | U = 15 V DC > typ. 2 mA < typ. 1.5 mA 2mH 250 nF 5 % 1 kHz yellow | | |
| | | -25...+70°C | | | -20..+90°C | | |
| | | | |
| | | |
| | | Degree of protection EC 529 Connection cable Housing material Active surface Lid | | IP 67 | | |
| | | |
| | | 2m 2 x 0.75 mm2 | | 2m 3 x 0.75 mm2 | | |
| | | |
| | | brass | | |
| | | |
| | | PVC PA | | PTFE PC | | |
| | | |
| | | No. 1 | | No. 2 | | |
| | | |
| | | RECHNER Industrie-Elektronik GmbH • Gaußstraße 8-10 • D-68623 Lampertheim • Tel. +49 (0) 62 06 50 07-0 • Fax +49 (0) 62 06 50 07-20 • email info@rechner-sensors.de • www.rechner-sensors.de 19 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |