Gas leak detector GSK - RBR-Computertechnik - #1

/ 2


catalogue search
Gas leak detector  GSK - RBR-Computertechnik
P. 01
Gas leak detector  GSK - RBR-Computertechnik
P. 02
Pages:
Gas leak detector  GSK - RBR-Computertechnik


See other catalogues for RBR-Computertechnik

Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:12.00pt "Arial", sans-serif; } .font4 { font:18.00pt "Arial", sans-serif; } .font5 { font:19.00pt "Arial", sans-serif; } .font6 { font:25.00pt "Arial", sans-serif; } .font7 { font:9.50pt "Franklin Gothic Medium", sans-serif; } .font8 { font:6.00pt "Georgia", serif; } leica DISTO™ D3 eCOfYT • Soot Pump • €COfTÎ • Smoll instrumentation Handy and small Laser distance meter Soot check device The Leica DISTO™ D3 offers plenty of functions and is simultaneously easy to operate. You measure distances with absolute accuracy in no time - also thru obstacles and determine angles quick and precisely. Furthermore the integral inclination sensor enables an absolute horizon­tal measurement. A further sensor identifies the light conditions and auto-matically switches on the display and keyboard backlit if need be. You can rely any time on your Leica DISTO™ D3 - even in the dark! The ecom soot pump is a high quality soot determination device. The proven technique used since years has been optimized one more time pro-viding with a reliable and long-lasting operation of this product which main features are characterized by an easy handling and a robust construction. The soot pump is obviously TŰV approved and still functions brilliantly, even after more than 1000 measurements. The main component of the pump, the cylinder and the pump head are made out of high-quality aluminium. The sampling probe, highly resistant to corrosion, is made out of high-grade steel. Technical data • Sampling volume: 1.63 +/- 0.07 l by 10 strokes within 60 seconds • Dimensions: 380 x 80 x 40 mm • Weight : 500 g Products Features • Minimum- and maximum measurement • Indirect measurement via Pythagoras • Recall of the last 20 measurements • Automatic release function Surface and volume measurement Addition/Subtraction Geometrical calculations Display backlit Indirect measurement via inclination sensor Techniscal data • Power supply: • Range: • Indication: • Accuracy • Dimensions: • Weight: Batteries: 2 x 1,5 V AAA 0.05 m to 100 m ± 45° 0,001 m 0,1° ± 1,0 mm ± 0,3° approx. 125 x 45 x 24 mm (L x W x H) approx. 110 g ecom • nu • Read-out head for firing automats The read-out head ecom-AK enables the recall of data gathered by digital firing automats. Information like trouble sources, error history, flame signal and operation voltage are received by the ecom-AK as optical signal at the troubleshooting button of the firing automat and shown on the graphic dis­play. Technical data • Power supply: 2 x accumulators type AA 1.2 V or 2 x batteries type AA 1.5 V • Current consumption: ca. 100 mA • Storage temperature: -20°C to +50°C • Operation temperature: -20°C to +50°C • Weight: 150 g (with batteries) • Dimensions : 88 x 41 x 32 mm • Delivered with protection bag and 2 batteries ecom tfs Energy Advisor Kit TFS with 4 instruments The Energy Advisor Kit TFS has been especially combined to fulfil all requirements set by the professional evaluation of the living climate of an inhabited space. The kit covers the following instruments: The sound level meter SL 328 (1) checks noise emissions in living spaces and with its range from 32 to 130 dB covers -acc. to the European norm EN 60651 Type 2- the total noise range from leaf rustling to taking-off Jumbo jets. The material humidity meter HumidCheck (2) completes the humidity val­ues gathered while determining the level in solid materials like building materials, walls or wood. Possible humid spots in a wall get quickly tracked and/or residual moisture in building or firewood stocks inspected and ascertained. The temperature/humidity instrument H560 (3) with integral dew point indication has a quick capacitive humidity sensor. The H560 shows the current air humidity, the dew point temperature and issues an optical warning by critical values. The laser infrared thermometer Scantemp 440 (4) measures within a frac­tion of a second the surface temperature without touching the object and is an ideal completion to the H560. Herewith also ceilings or remote sur­faces get comfortably measured. Especially the quick tracking of refriger­ation bridges or draught areas at external walls and Windows is one of the jobs the Scantemp performs with highest reliability. â ppm % °C hPa psi ppm % °C hPa psi ppm % °C hPa psi ppm % °C hPa psi ppm % °C hPa psi Contact below rbr agency for more infor Technical data Sound level meter SL 328 (1) • Range: 32 to 130 dB • Accuracy: ± 1.4 dB • Dimensions: 206 x 42 x 25 mm (L x W x H) • Weight: 1 Material humidity instrument HumidCheck (2) • Range: Building: 0.2 to 2.0% / Wood: 6 to 44% • Accuracy: Building: ± 0.05% / Wood: ± 1% • Dimensions: 130 x 40 x 21 mm (L x W x H) • Weight: 100 g Temperature/Humidity instrument H560 (3) • Range: -40 to 70°C / 0 to 99% rH • Accuracy: ± 0,5°C / ± 3% (20 to 90%) • Dimensions: 170 x 50 x 17 mm (L x W x H) • Weight: 100 g Laser infrared thermometer Scantemp 440 (4) • Range: -33 to 500°C • Accuracy: ± 2% / ± 2°C (higher value prevails) • Dimensions: 175 x 39 x 80 mm (L x W x H) • Weight: 180 g rbr Messtechnik GmbH • Am Grossen Teich 2 • D-58640 Iserlohn • Telefon +49(0)2371/945-5 • Fax +49(0)2371/40305 Internet www.rbr.de • E-Mail info@rbr.de

pageCatalog pdf di En 2012-02-07-15