M1144
8Pages

{{requestButtons}}

Catalog excerpts

M1144 - 1

These simple application boards constitute a bidirectional Mesh networked remote control system. Each board has 1-input, 1-output, a 4-bit global address and a 4-bit Unit ID (hence "M1144"). A complete system consists of a master board (which initiates communication burst cycles) and up to 15 slave units. Any input activation on any slave (or the master) closes the relays on all units on the system. This makes the M1144 an ideal platform for an alarm system. Features ■ 4-bit Global address, 4-bit Slave Unit ID selectable via 8-way DIP switch ■ 1 Master, 15 Slave Units per site ■ Unlimited number of drone receiver/decoders ■ Usable with any BiM footprint radios (up to 100mW) with a switching & settling time of <10ms ■ 5VDC 44mA or 12VDC 18mA relay to control devices rated up to 8A 250VAC or 5A 30VDC ■ Alarm response time <1s to 16s (worst case for whole network) ■ Frame synchronisation codes, check sums and address are used to prevent false triggering ■ 3.6kbps bi-phase data packet encodes the alarm status and presence of each slave unit on the network ■ 1.65% (132ms in 8s) Transmit Duty Cycle per slave unit ■ 8.8% (704ms in 8s) Maximum Radio Channel Occupancy per system ■ Visual LED indication of communication status and relay state ■ 4-times greater operating radius compared to a point-to-point system, using the same radio module ■ Logic or Switch input for momentary control of relay ■ 3.5mA average current (e.g. 34 weeks operating life from 6xD cells) ■ Simple “plug-and-play” setup. No complex programming needed Applications ■ Security and Alarm systems ■ Emergency assistance call system ■ Status reporting and monitoring systems ■ RF Remote control systems ■ Industrial controls Kit Contents The M1144 Application kit is supplied with the following contents: 1 M1144 Encoder/Decoder Master board 1 M1144 Encoder/Decoder Slave board 2 Radiometrix Transceiver module (ordered separately) 2 1/4-wavelength UHF monopole or VHF helical antennas depending on module frequency Additional requirement ■ External DC power supply

Open the catalog to page 1
M1144 - 2

M1144 controller and application board M1144 allows a network which is star based but 4-hops in all directions to enable a network which is 4 times as large as a standard simple star network. The boards are the same for both master and slave, it is just the M1444 firmware which is different for a master or a slave. Common features and characteristics of the M1144 boards Radiometrix Ltd M1144 Application Boards page 2

Open the catalog to page 2
M1144 - 3

Radiometrix Ltd M1144 Application Boards page 3

Open the catalog to page 3
M1144 - 4

Operational Description In an M1144 system, timing is everything. Data is only transmitted in carefully defined and synchronised timing "slots". The primary reference for this timing is generated by the Master unit, and is received (and re-sent) by the slave units to provide a consistent time reference across the whole network. A slave unit without valid synchronisation cannot transmit. The diagram (below) shows how the system timings are arranged. 50ms long Slot Burst Returning Reply Frames Outgoing Synchronisation Frames The basic timing element is a 50ms "slot" (into which a single...

Open the catalog to page 4
M1144 - 5

ML1144 timings and battery consumption The battery consumption is very important in this system and the synchronising system used allows the units to maximise battery life. For example, take the worst case, zone 2 or 3 radio, identity number 15. Idle current is approximately 100μA at 4.65 seconds in every 8 second group TX contribution: 750ms at 2.4mA (processing) 44ms TX actually ON, at 29mA three times over RX contribution: 850ms at 9mA (main listen) 100ms at 12mA (sync listen, LED on) In worst case sync (receiving a sync from a zone 2 unit with slave ID of 14) the sync listen...

Open the catalog to page 5
M1144 - 6

systems with the OD28 board for indication purposes. The OD28 allows the user to see units present and alarm states in the form of LED indicators. Figure 5: M1144 Application Board Schematics

Open the catalog to page 6
M1144 - 7

Ordering Information Note: For details relating to the radio module fitted on board, see relevant data sheet http://www.radiometrix.com/files/additional/bim1.pdf http://www.radiometrix.com/files/additional/nim2b.pdf Frequencies and options The mater and slave units can take any of the Radiometrix 10mW-100mW VHF/UHF transceiver units which have a BiM footprint and switching and settling time of less than 10ms, thereby offering a number of frequency and power options. Call sales on +44 20 8909 9595 to see what frequencies and power levels are available in your country. Radiometrix Ltd M1144...

Open the catalog to page 7
M1144 - 8

Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for...

Open the catalog to page 8

All Radiometrix catalogs and technical brochures

  1. BD118

    5 Pages

  2. LNM2H

    13 Pages

  3. NiM1B

    13 Pages

  4. VX2M

    9 Pages

  5. WRX2C

    9 Pages

  6. MSR3

    8 Pages

  7. LMR0

    10 Pages

  8. SAT3

    5 Pages

  9. NTX2B

    13 Pages

  10. NTX0

    8 Pages

  11. MTX3

    10 Pages

  12. MTX2

    10 Pages

  13. BiM3H

    8 Pages

  14. QPX1

    8 Pages

  15. QPT1

    8 Pages

  16. AiM1

    9 Pages

  17. DXT / DXR

    7 Pages

  18. BL118

    7 Pages

  19. BD118

    5 Pages

  20. PAN1311

    2 Pages

  21. PAN1310

    2 Pages

  22. m48a

    11 Pages

  23. LMR2

    11 Pages

  24. TDL3F

    10 Pages

  25. krx2

    9 Pages

  26. KTX2

    8 Pages

  27. RPM3

    15 Pages

  28. ENX1

    11 Pages

  29. NiM2

    11 Pages

  30. BiM1

    15 Pages

  31. RX3G

    6 Pages

  32. PLR2

    12 Pages

  33. MSR3

    8 Pages

  34. CXR2

    12 Pages

  35. COR3

    8 Pages

  36. TX2S

    7 Pages

  37. CXT2

    12 Pages

  38. KRX2

    9 Pages

  39. KFX2

    4 Pages

  40. KDEC

    5 Pages

  41. TXL2

    11 Pages

  42. Radiometrix

    20 Pages