video corpo

Service columns - 24 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

  11. P. 20

Catalogue excerpts

N° 222-CS ADVANCED FLUID MANAGEMENT SOLUTIONS

 Open the catalogue to page 1

ADVANCED FLUID MANAGEMENT SOLUTIONS

 Open the catalogue to page 3

ADVANCED FLUID MANAGEMENT SOLUTIONS at your service since 1975 RAASM works to offer the best through continuous improvement, in terms of performance, functionality and reliability of its products.

 Open the catalogue to page 4

5 YEARS WARRANTY Made In Italy HELP THE NATURE Packaging contains, depending on the articles, one or more of the following materials; they must be recycled in accordance with current regulations in the country of use. cardboard • polyethylene sack • polystyrene paper • wood • nails • plastic strap cellophane • clips • g

 Open the catalogue to page 5

Strength    FRONTAL Service columns are the ideal tool to use in working environments with no or little free spaces on the wall or no-supporting vertical surfaces. The wide range of models available allows to optimize and rationalize the working spaces, satisfying any work need with simplicity and ergonomic. • High resistance to shocks and wear over time thanks to solid steel structure with scratch-resistant paint or AISI 304 stainless steel. • A column for all series of hose reels thanks to the universal bracket holes that allow the attachment of all RAASM hose reels (except S. 540 and 560) and accessories. •...

 Open the catalogue to page 6

BILATERAL service columns FREQUENT QUESTIONS Can series 540 or 560 hose reels be mounted on the service columns? No, the following series can be mounted on the service columns: 250, 260, 280, 290, 300, 330, 390, 430, 450 and 530. Are there stainless steel service columns? Yes, articles 39421 and 39422 are in AISI 304 stainless steel and can accommodate, respectively, 1 and 2 hose reels. How can I empty the drip tanks? Technical characteristics BILATERAL service columns with collection tank The drip tanks have a 1/2” threaded hole with plug on the bottom. You can purchase a ball tap (P/N 38209)...

 Open the catalogue to page 7

ADVANCED FLUID MANAGEMENT SOLUTIONS APPLICATION FIELDS RAASM service columns are designed to work with flexibility in a lot of working environments, as workshops for cars and trucks. Waste oil suction version and AISI 304 stainless steel version are the other solutions which make the service columns family ideal for automotive and cleaning sectors. The most common working environments are: - automotive - cleaning - car washes - food industries - chemical industries - shipyards ...and many others

 Open the catalogue to page 9

Frontal service columns TECHNICAL CHARACTERISTICS F Solid steel structure with scratch-resistant paint. Some models have lateral holes for attaching Series 250, 260, 280 and 300 swivelling hose reels. Universal holes for attaching modular drip trays (not available for the stainless steel version). Universal holes for mounting hose reels (see quantities and models in the table on the inside pages). Base for anchoring to the floor. Internal preparation for mounting pulser mono-valve and bi-valve for operation with FCS system. The connection to the system can be made on either the ceiling or floor. CEILING...

 Open the catalogue to page 10

Frontal service columns with collection tank TECHNICAL CHARACTERISTICS D Solid steel structure with scratchresistant paint. Base for anchoring to the floor. Drip tank. It can be emptied by mounting the ball tap to be ordered separately. Articles 39351 and 39352 provide a containment tank for 1 or 2 drums. Internal preparation for mounting pulser mono-valve and bi-valve for operation with FCS system. Universal holes for mounting hose reels (see quantities and models in the table on the inside pages). The connection to the system is on the ceiling. Removable grill Convenient hose-holder hook for...

 Open the catalogue to page 11

FRONTAL service columns Frontal service columns. Installable on walls or like a delivery corner, they are connected with the centralized distribution system to work as an independent operational stations. Comfort and ergonomics also in narrow spaces Suitable for FCS system Ceiling or floor installation MAX NUMBER OF REELS CAN BE INSTALLED FOR SERIES COLUMNS FOR SUCTION Look the example on the left P/N 88630 Modular drip-tray equipped with hook for gun and removable drip-tray. Wall bracket in painted steel for diaphragm pumps 1/2” and 3/4” (for P/N 39320) Bracket in steel for mounting of suction...

 Open the catalogue to page 12

FRONTAL service columns Frontal service columns. Installable on walls or like a delivery corner, they are connected with the centralized distribution system to work as an independent operational stations. Comfort and ergonomics also in narrow spaces Suitable for FCS system Ceiling or floor installation P/N 88630 Modular drip-tray equipped with hook for gun and removable drip-tray.

 Open the catalogue to page 13

FRONTAL service columns Frontal service columns. Installable on walls or like a delivery corner, they are connected with the centralized distribution system to work as an independent operational stations. Suitable for FCS system Ceiling or floor installation MAX NUMBER OF REELS CAN BE INSTALLED FOR SERIES Series P/N 88630 Modular drip-tray equipped with hook for gun and removable drip-tray.

 Open the catalogue to page 14

FRONTAL service columns AISI 304 STAINLESS STEEL Frontal service columns. Installable on walls or like a delivery corner, they are connected with the centralized distribution system to work as an independent operational stations. Made in AISI 304 stainless steel are designed to be used also in the most aggressive environments. MAX NUMBER OF REELS CAN BE INSTALLED FOR SERIES

 Open the catalogue to page 15

FRONTAL service columns with collection tank Frontal service columns. Installable on walls, they are connected with the centralized distribution system to work as an independent operational stations. They have a comfortable drip-tray to recover any oil or fluids leaks, ensuring the cleaning of the floor. GOO Comfort and cleaning at work Max number of hose reels can be installed: 4 MAX NUMBER OF REELS CAN BE INSTALLED FOR SERIES P/N 38209 Ball valve M 1/2” G x F 1/2” G for emptying the drip-tank (mounting instructions on page 11).

 Open the catalogue to page 16

FRONTAL service columns with containment tank Frontal service columns. Installable on walls, they are connected with the centralized distribution system to work as an independent operational stations. They have a sturdy containment tank where load 1 or 2 tanks up to 180-220 Kg. GOO Comfort and cleaning at work Suitable for FCS system Ceiling installation MAX NUMBER OF REELS CAN BE INSTALLED FOR SERIES P/N 88630 Modular drip-tray equipped with hook for gun and removable drip-tray. Wall brackets in steel for mounting of suction pumps S. 600 and 650 (P/N 33115) and transfer and dispensing pumps S....

 Open the catalogue to page 17

All RAASM SpA catalogues and technical brochures

  1. TYRE INFLATOR

    2 Pages

    En
  2. WASHING TANK

    1 Pages

    En
  3. AdBlue hose reels

    20 Pages

    En
  4. RAM Hoists

    32 Pages

    En
  5. Manual hose reels

    40 Pages

    En