Miniature Circuit-Breaker IEC LS Series 8562 - 18 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

Series 8562/5 miniature circuit-breakers meet all technical requirements relating to safe and selective tripping. When short-circuits occur, they restrict the load on the installed circuits due to their excellent current limiting and related high breaking capacity and provide a high level of discrimination for lineside fuses. > 1 to 3 pole versions > Rated current from 0.5 ... 40 A > 6 or 10 kA breaking capacity to DIN VDE 0641, respectively EN 60898 > Isolating Function to EN 60947-2 > Permanently set thermal and magnetic trips > Power limitation class 3 Components for System Solutions E9/1

 Open the catalogue to page 1

Selection Table other versions and accessories on request E9/2 Components for System Solutions

 Open the catalogue to page 2

Miniature Circuit-Breaker IEC Series 8562 Selection Table Components for System Solutions E9/3

 Open the catalogue to page 3

Miniature Circuit-Breaker 1-pole Selection Table - Order Specific Configuration Version /    Version Breaking capacity AC AC UL Auxiliary contact    without E9/4 Components for System Solutions 8562/..-...4-... 8562/..-...5-... -005    8562/..--005

 Open the catalogue to page 4

Miniature Circuit-Breaker IEC Series 8562 Miniature Circuit-Breaker 1-pole Selection Table - Order Specific Configuration Version / Breaking capacity Version    Breaking capacity Auxiliary contact 1 CO Fault signal 1 CO Rated operational 6 current in A    10 Components for System Solutions E9/5

 Open the catalogue to page 5

Miniature Circuit-Breaker 1-pole + N Selection Table - Order Specific Configuration Version / Breaking capacity Version    Breaking capacity Auxiliary contact E9/6 Components for System Solutions ..4-... ..5-... ...-005 ...-010 ...-020 ...-030 ...-040 ...-060 ...-100 ...-130 ...-160 ...-200 ...-250 ...-320

 Open the catalogue to page 6

Miniature Circuit-Breaker 2-pole Selection Table - Order Specific Configuration Version / Breaking capacity Auxiliary contact Rated operational current in A Version AC AC AC / DC UL UL 135 % without 1 CO Fault signal 1 CO order spec. 0.5 1 2 3 4 6 10 13 16 20 25 32 Components for System Solutions E9/7

 Open the catalogue to page 7

Miniature Circuit-Breaker 2-pole Selection Table - Order Specific Configuration Version /    Version    Breaking capacity Auxiliary contact without    8562/..-...0-...    -- E9/8 Components for System Solutions 8562/..-...4-... 8562/..-...5-... -005    8562/..--005

 Open the catalogue to page 8

Miniature Circuit-Breaker 3-pole Selection Table - Order Specific Configuration Version / Breaking capacity Auxiliary contact Rated operational current in A Version    Breaking capacit without 1 CO Fault signal 1 CO 2 CO - 1 CO normal and fault signal 1 CO 0.5 1 2 3 4 6 10 13 16 20 25 32 Components for System Solutions E9/9

 Open the catalogue to page 9

Miniature Circuit-Breaker 3-pole Selection Table - Order Specific Configuration Version /    Version    Breaking capacity Auxiliary contact without    8562/ 1 CO    -Fault signal 1 CO    - 2 CO - 1 CO normal and fault signal 1 CO -- Miniature Circuit-Breaker 3-pole + N Selection Table - Order Specific Configuration Module width Order Number Width 99 mm 8562/54-4...- Order Number Supplement Version / Breaking capacity Auxiliary contact Rated operational current in A Version    Breaking capacity without 1 CO Fault signal 1 CO 2 CO - 1 CO normal and Fault signal 1 CO 6 10 13 16 20 25 32 E9/10 Components...

 Open the catalogue to page 10

Miniature Circuit-Breaker 3-pole + N Selection Table - Order Specific Configuration Version /    Version    Breaking capacity 2 CO - 1 CO normal and Fault signal 1 CO    8562/ Components for System Solutions E9/11

 Open the catalogue to page 11

Explosion Protection Marking lECEx Europe (ATEX) Certificates lECEx Europe (ATEX) Other certificates IECEx PTB 06.0062U PTB 02 ATEX 1049 U Belarus (Gospromnadzor) Technical Data Device version Version No. of poles Electrical data Version Rated operational voltage AC MCBs 1 pole, 1 pole + N, 2 pole, 3 pole, 3 pole + N AC / DC MCBs 1 pole, 2 pole AC MCBs Standard version AC    DC 1 pole    + N    230 V    - - AC / DC MCBs Standard version AC    DC 1 pole +    N    - -    - - Minimal Voltage Ubmin Maximal Voltage Ub max Rated insulation voltage 500 V    500 V Rated operational current Tripping characteristic...

 Open the catalogue to page 12

Miniature Circuit-Breaker IEC Series 8562 Technical Data Electrical data Tripping characteristic curves Components for System Solutions

 Open the catalogue to page 13

Technical Data Electrical data Tripping characteristic curves Selectivity class    3 (IEC/EN 60898) Breaking capacity    6 kA resp. 10 kA Rated switching capacities    AC MCBs Poles Series with 6 kA    Series with 10 kA DC to IEC/EN 609472 (Time constante 15 ms) Circuit breaker, current limiting with thermal and magnetic release E9/14 Components for System Solutions 2016-04-04-EK00-ili-en

 Open the catalogue to page 14

Technical Data Characteristics Characteristic to IEC/EN 60898 Rated current range Loads Normal temperature Thermal overload trip Thermal overload trip 135% UL Magnetic trip B 6 ... 32 A > Elektric heatings > Lighting > Socket outlet circuits > Control circuits e.t.c. 30 °C 1.13 ... 1.45 In > Operating equipment > Light fitting groups > Motors > Transformers D 0.5 ... 32 A > Operating equipment > Motors with heavy starting characteristic e.t.c. 30 °C 1.13 ... 1.45 In Components for System Solutions E9/15

 Open the catalogue to page 15

Technical Data Electrical data Response value of short-circuit trip Back-up protection The response value of the short-circuit trip is approximately 40 % higher for DC than for AC at 50 / 60 Hz Fuses must be fitted upstream to protect miniature circuit-breakers against high short-circuit currents in high power networks. These protect the miniature circuit-breakers against short-circuit currents of up to 50 kA. If a short-circuit occurs, both protective devices cut out simultaneously, so that the miniature circuit-breaker is not destroyed and remains fully functional. Following MCBs Type    MCB...

 Open the catalogue to page 16

Technical Data Mechanical data Degree of protection    Degree of protection acc. to IEC/EN 60529 Connecting terminals IP20 Material Enclosure    Epoxy resin Mounting / Installation Terminals    Main contacts 1.5 ... 10 mm2 clamp terminals Auxilliary contacts 1.5 mm2 clamp terminals Universal current +/-, 1 pole Universal current +/-, 2 pole Fault indication contact 1 CO Auxiliary contact 1 NO Fault indication contact 1 NO 12219E00 Auxiliary contact 1 CO Fault indication contact 1 CO Undervoltage trip Components for System Solutions E9/17

 Open the catalogue to page 17

All R. STAHL catalogues and technical brochures

  1. Ex-Poster

    1 Pages

    En
  2. BROCHURE: LIGHTING

    24 Pages

    En
  3. AK00 III

    12 Pages

    En
  4. EN/IEC 61439

    4 Pages

    En
  5. SERIES 200

    8 Pages

    En
  6. HMI Oil and Gas

    20 Pages

    En
  7. HMI Overview

    36 Pages

    En
  8. SolConeX

    12 Pages

    En
  9. GUBox

    4 Pages

    En
  10. EXLUX 6001

    4 Pages

    En
  11. Focus customer

    24 Pages

    En
  12. AK00 III

    5 Pages

    En
  13. 9160601310 de en

    24 Pages

    En
  14. Lighting

    16 Pages

    En
  15. Isolators

    6 Pages

    En
  16. Safety Barriers

    27 Pages

    En
  17. Ex Magazine 2012

    70 Pages

    En
  18. IS1+Remote I/O

    16 Pages

    En
  19. Stahl - Catalog

    1306 Pages

    En

Archived catalogues

  1. ISpac isolators

    16 Pages

    En
  2. IS1 remote I/O

    12 Pages

    En
  3. Fieldbus Solutions

    16 Pages

    En
  4. Cable glands

    18 Pages

    En
  5. Lighting

    16 Pages

    En
  6. Company brochure

    24 Pages

    En
  7. Marine Solutions

    24 Pages

    En