ET-406 – 10.4" (800 x 600) Highlights • Rugged Panel PCs for temperatures ranging between -40 °C up to +55 °C [-40 °F up to +131 °F] • Rugged, modular structured product design • Without additional enclosure suitable for use in hazardous areas / many enclosure and mounting options Explosion Protection Examination Certificate / Identification ATEX directive 94/9/EG TÜV 11 ATEX 7041 X ET-xx6-A-Tx II 2 (2) G Ex d e ia ib mb [ia ib] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib] IIIC T80°C Db IP66 ET-xx6-A-Fx II 2 (2) G Ex d e ia ib mb [ia ib op is] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib op is] IIIC T80°C Db IP66 IECEx TUR 11.0006X ET-xx6-A-Tx Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 ET-xx6-A-Fx Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 GOST-R РОСС DE.ГБ04.B01741 Operating licence РСС 00-047986 ET-xx6-A-Tx 2Exdeiaibmb[iaib]IICT4 DIP A21 TA80°C, IP66 ET-xx6-A-Fx 2Exdeiaibmb[iaibopis]IICT4 DIP A21 TA80°C, IP66 Firmware/Software • OPEN HMI – open for all software applications • Ready-to-run operating system in 25 languages • Windows Embedded Standard 2009 / 7 Ultimate • Optional installation of visualization software e. g. WinCC flexible® / Factory Talk View® / Vijeo Citect®, etc. Description The ET-406 Panel PC with high bright 10.4" screen and many customizable function keys is the ideal start into the ET-400 series – certified for use in hazardous areas zone 1, 2, 21, 22. This fullfledged PC can be integrated in the company network architecture, and is able to simultaneously and independently process other applications on-site. This HMI is highly versatile, with intuitive touch screen operation, and customizable softkeys and function keys. The ET-406 is ready-to-run worldwide, with pre-installed, multilingual Windows Embedded Standard 2009 or -7 Ultimate operating system (QNX, Linux optional) – without time-consuming installation of drivers or operating systems. All pre-installed operating systems are protected against external manipulations. In the rare case of a system failure, the BACKUP/RECOVERY solution via USB stick allows to immediately restore the original state. Thanks to the modern heat pipe technology combined with protection screen and enclosure heater, the Panel PC operates at temperatures ranging between -40 °C up to +55 °C (+50 °C in permanent operation / with heater and protection screen -40 °C). NEC / UL 20130611-E202379 Class I, Division 2, Groups A, B, C, D Class II, Dvision 2, Groups F, G Class III Hazardous Locations Class I, Zone 2, Group IIC CEC / CSA 2512677 Ex d e ia ib mb [ia ib] IIC T4 Gb, Type 4X, IP66 Ex ia tb [ia ib] IIIC T80°C Db, IP66 Class II, Division 1, Groups E, F, G, T80°C We reserve the right to make any changes at any time according to technological progress or further development. R. STAHL HMI Systems GmbH | Im Gewerbegebiet Pesch 14 | D 50767 Köln | www.stahl-hmi.de Tel. +49 (221) 59808-200 | Fax: +49 (221) 59808-260 | Email: office@stahl-hmi.de

 Open the catalogue to page 1

CNEX (China) DNV(DetNorske Veritas) Ingress protection Front and back side IP66 Operating Principle SAFE AREA Engineering / Automation Windows Server™ Siemens WirCC flexible Rockwell Factorv Talk View Schneider Uijea Cited Windows Embedded We reserve the right to make any changes at any time according to technological progress or further development. R. STAHL HMI Systems GmbH | Im Gewerbegebiet Pesch 14 | D 50767 Koln | www.stahl-hmi.de

 Open the catalogue to page 2

Technical Data Mounting design Front panel mounting 26 cm (10.4") TFT color display 16.777.216 colors SVGA 800 x 600 Aspect ratio 4:3 Brightness 400 cd/m² Contrast 700:1 8 wire resistive touch screen as standard LED technology Service life 130,000 h at +10 °C [ +50 °F] 55,000 h at +35 °C [ +95 °F] 40,000 h at +55 °C [+131 °F] Display function keys 12 function keys 10 soft keys Cursor keys 12 alphanumeric keys 14 system keys Polyester film on aluminum plate External keyboard Yes (optional), 105 / 107 keys, incl. trackball / joystick (Ex ia) 4 / 16 GB, 128 GB MLC / SLC (Solid State Card) Memory...

 Open the catalogue to page 3

ET-406 – 10.4" (800 x 600) NO. DS200640140100 | EN 2014 | V 03.02.11 Permissible ambient temperature ranges Operation -20 °C up to +55 °C* [ -4 °F up to +131 °F] Operation with heater ** -30 °C up to +55 °C* [-22 °F up to +131 °F] Operation with heater **, enclosure insulation, protection screen -40 °C up to +55 °C* [-40 °F up to +131 °F] Storage -30 °C up to +60 °C [-22 °F up to +140 °F] * ET-4x6-A and ET-5x6-A: 5 h maximum operation at +55 °C [+131 °F]; continuous operation (24/7) at +50 °C [+122 °F] ** The heater has to be designed to ensure that the temperature inside the enclosure of the...

 Open the catalogue to page 4

All R. STAHL HMI Systems GmbH catalogues and technical brochures

  1. Process Industry

    28 Pages

    En
  2. HMI Overview

    36 Pages

    En
  3. The new 200 series

    12 Pages

    En