PCUS 40

Ultrasonic Components PC System: 4 transmit/receive channels per module, expandable to 4 more transmit/receive channels for a total of 8 transmit/receive channels (optional modules) Rack-mount System: 4 transmit/receive channels per module, expandable a total of 64 transmit/receive channels (optional modules, 4 channels each) Options: ˝ size analog board with 4 channels and full size analog board with 8 channels Transmitter Pulse: Spike pulse Transmitter Voltage: 50, 100, 150, 200, 250 V
pp for one individual scan cycle Transmitter Output Impedance: 50 Ω Pulse Repetition Rate: ≤ 5 kHz, dependent on selected sweep range and sampling rate, adjustable Input Dynamic: 97 dB with narrow-band filter 1MHz 85 dB with broad-band filter (0.3 – 15 MHz) Frequency Range (-3 dB): 0.3 – 15 MHz Amplitude Characteristics (Receiver): Linear, logarithmic (optional) Variable Gain/TGC: 40 dB, 0.2 dB resolution Pulse Mode: Pulse-Echo (P/E), Transmit/Receive (T/R) Analog Boards (4 Channels): ˝ size ISA (16 bit), 166mm x 127mm Digital Boards (2): Full size ISA (16 bit), 332mm x 127mm, and ADC clip-on Data Processing A/D Converter: 1 ADC 10 bit (9 bit & header), 80 MS/sec 1 ADC 12 bit (11 bit & header), 40 MS/sec A/D Converter Dynamic: 54 dB for 10 bit ADC 66 dB for 12 bit ADC A/D Converter Rate: 80 MS/sec (10 bit ADC), 40 MS/sec, 20 MS/sec, 10 MS/sec, adjustable Standard A-scan data: Standard RF data: Half-wave peak data: Pixelized A-scan data: Gated data: ALOK data: Included Included Add-on board (optional) Add-on board (optional) Add-on board (optional) Peak Detector board (optional) Number of Scan Cycles: 256, individually programmable Maximum Cycle Rate: 1 kHz Scan Speed: Dependent on internal bus clock (20 MHz), Cycle processing delay (30 µ sec) and Processing time (min. 170 µ sec) Data Acquisition Rate: 480 Kbytes/sec, on-line display of 4 A-scans and writing to HDD simultaneously (60 MHz Pentium processor) Scan Cycle Triggering: Position, time, manual, external 128 programmed scan trigger functions can be activated/deactivated PCUS 40 Datasheet, March 2001
This document contains information proprietary to QUALITY NETWORK INC.; it is submitted in confidence and is to be used solely for the purpose for which it is furnished and returned upon request. This document and such information is not to be reproduced, transmitted, disclosed, or used otherwise in whole or in part without the written authorization of QUALITY NETWORK, INC. Page 1 of 2