Q-SUN Xenon Test chambers
Q-Sun Overiew
All testers include: All models of the Q-Sun are equipped with: full-spectrum xenon arc lamps; the patented Solar Eye Irradiance Control System; a choice of irradiance set points (340 nm or 420 nm); a choice of filters (see below); chamber air temperature control; black panel temperature control; the patented AutoCal system that allows quick and easy calibration; and a large specimen capacity to accommodate 3D parts.
All testers having the following options availabe: Strip chart recorder, RS232 Computer Interface, Textile/Thin Film Specimen Holders, and Textile Masks.
Recognition: The Q-Sun meets most test methods, including: ASTM, ISO, DIN, SAE, BS, ANSI, and AATCC. For a full list of Q-Sun test methods ask for Bulletin LX-5054.
Irradiance Control:
The Q-Sun is equipped with the Solar Eye Irradiance Control System. Solar Eye automatically compensates for lamp aging and any other variability. Depending upon the model, you can control the light intensity at either 340nm or 420nm.
Choice of one (1) control point: 340nm or 420nm
• 0.25 - 0.68 W/m2 @ 340 nm with Daylight: Q, Daylight: B/B,
Extended UV: Q/B, Quartz
• 0.25 - 0.55 W/m2 @ 340 nm with Window: Q, Window: B/SL
• 0.45 - 1.50 W/m2 @ 420 nm with Daylight: Q, Daylight: B/B,
Window: Q, Window: B/SL, Extended UV: Q/B, Quartz or IR Filter ® Higher irradiance values are posssible, but lamp life is reduced.
Calibration:
• Irradiance Calibration (Auto Cal) use CR20 Radiometer.
• Relative Humidity calibration use CH200 RH Calibration Kit.
Xenon Arc Lamps:
The Q-Sun uses air-cooled, full-spectrum, 1800W xenon arc lamps. The Xe-3 requires 3 lamps, the Xe-1 requires 1 lamp. Q-Panel recommends replacing lamps every 1500 testing hours.
The exposure application or test protocol dictates which filter should be used. The filters do not need to be replaced unless they are physically broken.
• Daylight: Q
• Daylight: B/B
• Window: Q
• Window: B/SL
• Extended UV: Q/B
• IR: (Infrared Exclusion)
• Quartz
® All calibrations are NIST traceable for ISO compliance.
® Radiometers must be sent back to Q-Panel for recalibration every year.
Temperature Control:
Simultaneous Chamber Air and Black Panel Temperature Control is possible in models: Xe-3-H, HS, HC, HSC, and HDS.
Q-Panel Lab Products World Headquarters 800 Canterbury Road Cleveland, OH 44145 USA Phone: 440/ 835-8700 Fax: 440/ 835-8738 info@q-panel.com www.q-panel.com
Q-Panel Lab Products European Headquarters: Express Trading Estate Farnworth, Bolton England BL49TP Phone: +44 (0)1204 861616 Fax: +44 (0)1204 861617
Q-Panel Lab Products China Sales Office: Room 1809, Liangyou Building 618 Shangcheng Road Pudong District Shanghai, China 200120 Phone: 0086-21-5879-7970 Fax: 0086-21-5879-7960
The Most Trusted Name in Weathering