PURÎIE
FIRST FOR PURE WATER
Operating data: permeate conductivity (temperature corrected), permeate temperature, operating hours, feed water conductivity, percentage salt rejection.
Alarm signals: low pressure, hard water, motor overload, high conductivity pre-alarm, high conductivity fault, concentrate fault. Status signals: permeate discard, permeate recycling, concentrate displacement, concentrate rinse, intermittent rinse during shut­down, shut-down by external signal (forced stop, regeneration). LEDs for operation, alarms, regeneration, discard, disinfection, full tank and rinse.
Input (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit. The Puritron 1000 control system includes control functions for the hardness monitoring unit. Freely programmable universal input with LCD, additional conductivity measuring unit (e.g. for feedwater). Shut-downs by external signal (forced stop, regeneration).
Outputs for 2 solenoid valves for concentrate flushing, permeate discard and recycling, second high pressure pump, analogue signal (e.g. 4-20 mA) and DDC (freely programmable universal output with LCD, conductivity alarm contact and collective alarm signal, each on floating changeover contact).
ELITEPLUS Reverse Osmosis Units 500 ND - 2500 ND
UNIT DESIGN
Stainless steel base frame with plastic front panel to house the instruments and controls.
Special inlet filter, stainless steel, with 5 urn filter cartridge and 2 pressure gauges.
High pressure pump, low-noise, multi-stage centrifugal type. Low energy wound modules with energy saving PA/PS composite membranes in GRP pressure vessels with PP inliner. Valves and instruments including feedwater sampling valve, solenoid/diaphragm inlet valve, feedwater pressure switch, permeate, concentrate and concentrate recirculation flow meters, vibration-resistant pressure gauges for pump and concentrate pressure, stainless steel adjustment valves for permeate, concentrate and concentrate recirculation flow.
Puritron 1000 microprocessor control system for fully
automated monitoring and control of the reverse osmosis unit with LCD (16 characters per line).
500 ND 750 ND 1000 ND 1300 ND
Technical Data
PERMEATE FLOW RATE
l/h
499
748
997
1247
MIN. SALT REJECTION
%
97
97
97
97
MAX. RECOVERY
%
75
75
75
75
VOLTAGE
V/ph/Hz
400/3/50
400/3/50
400/3/50
400/3/50
MOTOR POWER
kW
2.2
2.2
2.2
2.2
FEEDWATER CONNECTION
DN
20
20
20
20
PERMEATE/CONCENTRATE CONNECTIONS
DN
20
20
20
20
MIN./MAX. FEEDWATER PRESSURE
bar
2/6
2/6
2/6
2/6
MIN./MAX. FEEDWATER
TEMPERATURE
°C
5/35
5/35
5/35
5/35
HEIGHT
mm
1650
1650
1650
1650
WIDTH
mm
660
660
660
660
DEPTH
mm
690
690
690
690
WEIGHT (APPROX.)
kg
135
150
180
195
V
J
1500 ND 1800 ND 2000 ND 2500 ND
Technical Data
PERMEATE FLOW RATE
l/h
1496
1745
1995
2493
MIN.SALT REJECTION
%
97
97
97
97
MAX. RECOVERY
%
75
75
75
75
VOLTAGE
V/ph/Hz
400/3/50
400/3/50
400/3/50
400/3/50
MOTOR POWER
kW
3
3
3
3
FEEDWATER CONNECTION
DN
25
25
25
32
PERMEATE/CONCENTRATE
CONNECTIONS
DN
20
20
25
25
MIN./MAX. FEEDWATER
PRESSURE
bar
2/6
2/6
2/6
2/6
MIN./MAX. FEEDWATER
TEMPERATURE
°C
5/35
5/35
5/35
5/35
HEIGHT
mm
1650
1650
1650
1650
WIDTH
mm
2500
2500
2500
3500
DEPTH
mm
750
750
750
750
WEIGHT (APPROX.)
kg
240
280
320
360
1 J
The units are designed for a maximum TDS of 1000 mg/I, sized on a water temperature of 10 °C and a maximum colloidal index of 3. With new units the working presssure is about 15% lower. The permeate recovery depends on the raw water quality and the type of pretreatment.
Errors and omissions excluded. Purite reserves the right to change specification without notice.
SS0002-01
INVESTOR IN PEOPLE
Purite Limited, Bandet Way, Thame, Oxon OX9 3SJ, UK. Tel: +44 (0)1844 217141 Fax: +44 (0)1844 218098 Email: mail@purite.com Web site: www.purite.com