| | | FIRST FOR PURE WATER Operating data: permeate conductivity (temperature corrected), permeate temperature, operating hours, feed water conductivity, percentage salt rejection. Alarm signals: low pressure, hard water, motor overload, high conductivity pre-alarm, high conductivity fault, concentrate fault. Status signals: permeate discard, permeate recycling, concentrate displacement, concentrate rinse, intermittent rinse during shutdown, shut-down by external signal (forced stop, regeneration). LEDs for operation, alarms, regeneration, discard, disinfection, full tank and rinse. Input (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit. The Puritron 1000 control system includes control functions for the hardness monitoring unit. Freely programmable universal input with LCD, additional conductivity measuring unit (e.g. for feedwater). Shut-downs by external signal (forced stop, regeneration). Outputs for 2 solenoid valves for concentrate flushing, permeate discard and recycling, second high pressure pump, analogue signal (e.g. 4-20 mA) and DDC (freely programmable universal output with LCD, conductivity alarm contact and collective alarm signal, each on floating changeover contact). | | |
| | | ELITEPLUS Reverse Osmosis Units 500 ND - 2500 ND UNIT DESIGN Stainless steel base frame with plastic front panel to house the instruments and controls. Special inlet filter, stainless steel, with 5 urn filter cartridge and 2 pressure gauges. High pressure pump, low-noise, multi-stage centrifugal type. Low energy wound modules with energy saving PA/PS composite membranes in GRP pressure vessels with PP inliner. Valves and instruments including feedwater sampling valve, solenoid/diaphragm inlet valve, feedwater pressure switch, permeate, concentrate and concentrate recirculation flow meters, vibration-resistant pressure gauges for pump and concentrate pressure, stainless steel adjustment valves for permeate, concentrate and concentrate recirculation flow. Puritron 1000 microprocessor control system for fully automated monitoring and control of the reverse osmosis unit with LCD (16 characters per line). | | |