Produal Oy Customer oriented expertise in measurement technology Produal is an internationally operating pioneer of building automation measurement technology. The steady growth along with our customers during last years has enabled developing our operations according to the requirements of modern building construction. Reliable and accurate measurements facilitate the monitoring of energy efficiency, improve interior air quality and increase the comfort of occupants of the buildings. Understanding the emerging requirements of building automation forms the foundation for our operation. We...

Open the catalog to page 2
Catalogue 2013 - 4

alarm contact output 60 Vdc, 1 A input /output signal 0...10 Vdc, 10 mA JVA 24 1110110 forecasting, regulating; selectable sensor type (PtIOOO, NilOOO-LG, PTC 1000/2000) JVS 24 1110120 adjustable forecasting, regulating; selectable sensor type (PtIOOO, NilOOO-LG, PTC 1000/2000) alarm contact output 60 Vdc, 1 A input / output signal 0(2)...10 V, 10 mA housing IP20, 11-pole relay housing EJV 24-PT 1110080 for PtIOOO sensor (1000 Q / 0 °C), AR 1 relay included JV 24-PT 1110090 for PtIOOO sensor (1000 Q / 0 °C), contact output 50 Vac 6 A res. HIGH TEMPERATURE ALARM High temperature alarm relay...

Open the catalog to page 4
Catalogue 2013 - 5

ELECTRONIC THERMOSTATS LK 24-PT is a thermostat with an external Pt1000 temperature sensor input. °C supply 24 Vac/dc, 2 VA range -30…+30 °C or 0…+100 °C input sensor input, Pt1000 (1000 Ω / 0 °C) output 1 change-over contact, 230 V, 5 A res., by using AR 1 relay, 230 Vac, 10 A output 2 0…10 V = -30…+30 °C or 0…10 V = 0…+100 °C housing IP20, 11-pole relay housing Type LK 24-PT 3 art no. LK 24-PT 0/100 1120050 electronic thermostat, range -30…+30 °C 1120051 electronic thermostat, range 0…100 °C ELECTRONIC THERMOSTATS LEK 24-PT is a temperature difference thermostat with two external Pt1000...

Open the catalog to page 5
Catalogue 2013 - 6

Frankfurt Airport heathrow Airport P R O D UA L l 6 l C atalo g u e

Open the catalog to page 6
Catalogue 2013 - 7

AIR velocity TRANSMITTERS IVL air velocity transmitters are designed for measuring flow velocity inside the duct. Provided also with a temperature output. supply 24 Vac/dc, < 1,5 VA range, velocity IVL 10: 0…10 m/s, IVL 02: 0…2 m/s, IVL 20: 0…20 m/s range, temperature 0…+50 °C output 1 velocity = 0…10 V < 2 mA or 4…20 mA < 600 Ω output 2 temperature 0…+50 °C = 0…10 V < 2 mA or 4…20 mA < 600 Ω ambient temperature 0…+50 °C stem 10 mm x 200 mm housing IP54, stem or cable gland downwards mounting m/s, °C with flange, adjustable probe depth Type 4 art no. IVL 10 1130010 air velocity transmitter...

Open the catalog to page 7
Catalogue 2013 - 8

DIFFERENTIAL PRESSURE TRANSMITTERS FOR AIR PEL differential pressure transmitters are designed for clean / isolation room applications. The transmitter zero point is kept accurate by using the regular automatic zeroing, eliminating the possible zero point drifting. supply 4 24 Vac/dc, 1.5 VA range selectable at commissioning output 0…10 Vdc < 2 mA or 4…20 mA < 900…1200 Ω zeroing automatic; regularly eliminates the possible Pa zero point drifting ambient temperature -10…+45 °C housing IP54, cable gland downwards mounting with screws, external lugs Type art no. PEL 1131110 ranges 0…100,...

Open the catalog to page 8
Catalogue 2013 - 9

range selectable at commissioning zeroing manual; process connections must be removed before zeroing housing IP54, cable gland downwards mounting with screws, external lugs PEL 1000-N 1131141 with display, ranges identical with PEL 1000 PEL-AS 1131010 PEL accessory kit, includes 2 m hose and duct assemblies IML is designed for detecting and controlling air flow in air handling units and rooms. IML-M has RS-485 connection for Modbus RTU communication range selectable at commissioning output 2, diff. pressure or control 0...10 Vdc, < 2 mA input, external set point 0...10 Vdc, < 2 mA housing...

Open the catalog to page 9
Catalogue 2013 - 10

PP air flow probes are designed for detecting air flow in the air handling systems. Different models with fixed Kv values are available for circular and rectangular ducts. PP-PK R100 1250010 air flow volume probe for a circular 100 mm duct PP-PKR125 1250020 air flow volume probe for a circular 125 mm duct PP-PK R160 1250030 air flow volume probe for a circular 160 mm duct PP-PK R200 1250040 air flow volume probe for a circular 200 mm duct PP-PK R250 1250050 air flow volume probe for a circular 250 mm duct PP-PK R315 1250060 air flow volume probe for a circular 315 mm duct PP-PK R355 1250065...

Open the catalog to page 10
Catalogue 2013 - 11

HUMIDITY TRANSMITTERS KLH and KLH-M room humidity transmitters are designed for detecting indoor relative humidity and temperature. supply 24 Vac/dc, 1 VA range 1 0…100 % rH range 2 0…+50 °C output 1, % rH 0…10 V = 0…100 % rH, 2 mA output 2, °C 0…10 V = 0…+50 °C, 2 mA housing IP20, ABS plastic mounting room % rH, °C with screws on wall or on a junction box (hole distance 60 mm) 4 Type art no. KLH 100 1132210 room humidity transmitter KLH 100-N 1132211 room transmitter with display (humidity and/or temperature display) KLH-M 1132600 room humidity transmitter for Modbus RTU gateway KLH-M-N...

Open the catalog to page 11
Catalogue 2013 - 12

HUMIDITY TRANSMITTERS KLHJ 100 transmitters are designed for detecting relative humidity and temperature. The probe cable length is 2 m. room/duct % rH, °C supply range 1 0…100 % rH range 2 -50…+50 °C output 1, % rH 4 24 Vac/dc, < 1 VA 0…10 V < 2 mA / 4…20 mA < 600 Ω = 0…100 % rH output 2, °C 0…10 V < 1 mA / 4…20 mA < 600 Ω = -50…+50 °C ambient temperature -50…+50 °C sensor cable 2m housing IP54, cable gland downwards, (sensor IP50) mounting transmitter with screws (external lugs), sensor with flange, adjustable probe depth < 150 mm Type art no. KLHJ 100 1132260 KLHJ 100-N 1132261 humidity...

Open the catalog to page 12
Catalogue 2013 - 13

CONDENSATION SWITCH Condensation switch KA 10 is designed for detecting water condensation in cooling systems, for example in cooling beams. With the condensation switch it is possible to control the cooling water supply when the water starts to condensate on the pipe. The KA 10-EXT model has an external condensation sensor. supply 24 Vac/dc outputs condensation information 0...10 Vdc relay output 24 Vac/dc, 2 A cable gland 0...10 V output, relay output M16 4 ambient temperature 0...50 °C housing IP54, cable gland downwards Type art no. KA 10 1187030 condensation switch KA 10-EXT 1187031...

Open the catalog to page 13