Text version of the page
www.proceq.com pull-off tester • Determining the adhesive strength on concrete structures and the tension strength of concrete Testing is carried out directly on the structure. It can be measured on any point of the structure. For the determination of the tension strength it is not necessary to install test devices prior to the casting of the concrete. It is ideal for the evaluation of strength in concrete renovation. • Advantages • mobile for use in any location • independent of mains supply thanks to easy running crank drive • constant jerk-free load increase • weights only 3.5 kg (standard unit Z16) • Measuring the adhesive strength of applied coatings such as plastic coatings, concrete coats, mortars and plasters, bituminous coats and paint finishes and coatings on metal. • Indispensable for • diagnosing damage to building structures • checking of completed renovation/repair work DYNA Z units with digital manometer T echnical Information DYNA Tensile force Resolution Accuracy Permissible stroke Z16 16 kN 0.01 N/mm˛ < 2% 3.5 mm Z6 6 kN 0.01 N/mm˛ < 2% 4.0 mm The legs can be moved and/or lengthened on all models to adapt the positioning to the different test situations. display: up to five different units (e.g. N/mm˛ for test disc of 50 mm dia., force in kN) battery: type CR 2430 for manometer for 150 hours operation Weight: 3.5 kg Standards: ISO 4624, EN 1015-12, EN 1348, BS 1881 Part 207, ASTM C 1583, ASTM D 4541, ACI 503-30, DIN 1048 Part 2

pageCatalog pdf di En 2012-05-22-31