MAX COMMAND REFERENCE MANUAL 1-45 APP ARCHIVE CURRENT PARAMETERS AS POWER-UP DEFAULTS The APP command stores the current parameter set as the power-up default set of values. This is done by writing the current parameter set to flash memory. The following list of parameters can have their values saved to flash memory: AC, AO, BC, BD, BR, DBI/DBN, EDI/EDN, EH, EHD, ER, ES, HD, HG, HT, HV, KA, KB, KD, KF, KI, KO, KP, KU, KV, LM, LT, SC/SS/AJ, PA, PAA, PS, SE, SK, SV, TL, VB, VL, #UR and UU. Note: This command should not be issued when an axis is in motion and it should be used sparingly because the flash memory has a limited number of write cycles. Example: Save the current parameter set to be the power up default set of values. Enter: APP; Response: None. QUEUE REQUIREMENTS FORMAT MODE COMMAND ARGUMENT APP; Single Axis Immediate APP; AA-AM Immediate Related commands: RDB, RDF, RDP