| | | PT TF Transit Time Ultrasonic Flow Meter Part Numbering Information Integral System - 1/2" to 2" | | |
| | | |
| | | PTTF □ □ □ | | |
| | | 1 - N N | |
| | | |
| | | T | |
| | | |
| | | Display Options 1 - No display-ABS enclosure 2 - Rate & Totalizer display- ABS enclosure 3 - No display -polycarbonate enclosure 4 - Rate & Totalizer display- polycarbonate enclosure | | |
| | | 1 - 4-20 mA and Pulse | | |
| | | |
| | | Connector Options N - 1/2 Inch conduit hole A - Water-tight cable clamp С - Circular MIL-style connector D - 1/2 Inch flexible conduit connector | | |
| | | |
| | | |
| | | Pipe Size | | |
| | | |
| | | A - 1/2 inch ANSI Pipe B - 3/4 inch ANSI Pipe C - 1 inch ANSI Pipe D - 1-1/4 inch ANSI Pipe E - 1-1/2 inch ANSI Pipe F - 2 inch ANSI Pipe | | G - 1/2 inch Copper H - 3/4 inch Copper I - 1 inch Copper J - 1-1/4 inch Copper K - 1-1/2 inch Copper L - 2 inch Copper | | M - 1/2 inch Tubing N - 3/4 Inch Tubing P - 1 Inch Tubing Q - 1-1/4 Inch Tubing R - 1-1/2 Inch Tubing S - 2 Inch Tubing | | 1 - 20 mm Tubing 2 - 25 mm Tubing 3 - 32 mm Tubing 4 - 40 mm Tubing 5 - 50 mm Tubing 6 - 63 mm Tubing | | |
| | | (Consult factory for availability) | | |
| | | |
| | | |
| | | Remote System - 1/2" to 100" (A system consists of one PTTF part number and a choice of one large or small pipe transducer part number.) | | |
| | | |
| | | | | |
| | | | | |
| | PTTF | | | | | | | | | | T System Size X - Large Pipe Y - Small Pipe | — | | | | Select Options from Integral System Table above | | | | | | | | | 1 N | |
| | | | |
| | | |
| | | Large Pipe Transducer - 2" to 100м P T T - - N | | |
| | | Small Pipe Transducer - 1/2" to 2" P T T s - - | | |
| | | |
| | | |
| | | Nominal Pipe Size D - 1/2 inch F - 3/4 inch G - 1 inch H - 1-1/4 inch J - 1-1/2 inch L - 2 inch Pipe Type — | | |
| | | Type- N - Standard (CPVC, Ulteme) H - High temp (TFP, Vespel®) | | |
| | | Cable Length - 020 - 20 feet (6.1 m) 050 - 50 feet (15 m) 100 - 100 feet (30 m) | | |
| | | |
| | | Cable Length- 020 - 20 feet (6.1 m) 050 - 50 feet (15 m) 100 - 100 feet (30 m) | | |
| | | Location N - Ordinary area | | |
| | | |
| | | |
| | | Conduit Type - N - None - Bare RG59 cable A - Flexible armored | | |
| | | |
| | | |
| | | P - ANSI Pipe С - Copper Pipe T - Tubing | | |
| | | Conduit Type- N - None - Bare RG59 cable A - Flexible armored | | |
| | | Conduit Length 000 - 0 feet (0 m) 020 - 20 feet (6.1 m) 050 - 50 feet (15 m) 100 - 100 feet (30 m) | | |
| | | |
| | | Conduit Length - 000 - 0 feet (0 m) 050 - 50 feet (15 m) 020 - 20 feet (6.1 m) 100 - 100 feet (30 m) | | |
| | | |
| | | |
| | | |
| | | |
| | | Accessories Part Number PC Cable w/UltraLink™ software PTTF-ULINK 90-240 VAC Power Supply PTTF-ACPWR | | |
| | | Ultem is a registered trademark of General Electric Company. Vespel is a registered trademark of E.I. duPont Nemours and Company. | | |
| | | |
| | | |