You may also be interested in
Ultrasonic flow-meter, Valve, Shut-off valve, Ball shut-off valve, Differential pressure flow-meter
Text version of the page
Model AR Ellipse®
Annular Flow Meter
1-800-632-7337 www.preso.com
Specifications
Applications: Liquids and Gases
Pipe Sizes: 2 to 72 inches (50 to 1830 mm)
Pressure: 800 PSI (5515 kPa) max.
Temperature: 800 °F (426 °C) max.
Accuracy: ± 0.75% of reading
Turndown Ratio: 17:1 with no vacuum effect
Standard
Components: T-type head, 316 SS ¼" or ½" FNPT connection
CS compression fitting with SS ferrule
CS 3000 lb. weld fitting – ASTM A105
316/316L SS Ellipse sensor
Instrument valves (2 per sensor) – ¼", CS
316 SS ID tag with wire
Reynolds
Number: Greater than 75,000 maintains most accurate
flow measurements
Less than 75,000 consult factory for
estimated results
Resonance: If greater than 0.8, use double support
The multi-ported, self averagingflow
element consists of an elliptical shape with
two independent flow sensing chambers.
The impact velocity sensing holes (high
pressure) are located along the leading
edge and the true static sensing holes
(low pressure) are on the
exterior probe side. Model AR
comes with instrument
shut-off valves with
provisions to accept a
transmitter or direct
indicating meter.
F L O W M E T E R I N G E Q U I P M E N
®
Patented elliptical design outperforms traditional devices
Single point pipe entry for DP, temperature and static pressure
No dampening software required
Lowest pressure loss in industry (typically 3% of DP in a 12" line)
due to its patented aerodynamic profile
NIST traceable calibration: Optional independent labs
Features
Benefits
Accuracy: ±0.75% of reading, repeatability: ±0.1% of reading
Turndown Ratio: 17:1; no vacuum effects
No moving parts equals long, trouble-free service life
True static pressure measurement rather than a calculated value
Overcomes loss of accuracy caused by fluid separation
at the sensor body
Preso’s patented elliptical design outperforms and
provides greater accuracy than traditional differential
pressure flow measurement devices. This differential
pressure flow meter is designed with a series of ports
facing the upstream velocity pressures, as well as flow
sensing ports strategically located ahead of the trailing
edge flow separation.
True static
sensing holes
Impact velocity
sensing holes
RACINE FEDERATED INC.