eFLAT-E - PREMOSYS - #1

/ 2


catalogue search
eFLAT-E - PREMOSYS
P. 01
eFLAT-E - PREMOSYS
P. 02
Pages:
eFLAT-E - PREMOSYS


See other catalogues for PREMOSYS

Text version of the page
Premosys GmbH HIGIS-Ring 20 D-54578 Wiesbaum info@premosys.com www.premosys.com Tel.: ++49 (0) 6593 – 99 86 82 Fax.: ++49 (0) 6593 – 99 86 84 eFlat Flexible Light Analyzer and Test System LED Color Test still more simple and more surely eFLAT is the next generation of LED Color test systems. It serves for the parallel test of color and intensity of self –luminous objects – especial LED’s – in the visible area of light. With this system from 4 up to 16 LED’ can be tested in parallel due to the 4 different product variants. The color and intensity of the test objects can be parameterized and evaluated independently. The test time is approx. 300 ms. Parasitic inductions by ambient light are compensated automatically. The measurement procedure is based on comparative measurements on the basis of reference products by means of user specific parameters. eFLAT can be “trimmed” to a very high absolute accuracy by using calibration functions. As well the customer can clearly increase the absolute accuracy by performing own calibrations by using own measurement equipment. eFLAT has an excellent price performance ratio, is very fast and easy to handle, tests up to 16 LEDs in parallel and shows an excellent selectivity between LED types and adjacent binnings. Accuracy: White reference: Chromaticity coordinate x, y +/- 0,0015 Rel. intensity +/ 2% Resolution CCT 100 K Monochromatic LED: Ldom <+/- 4nm Resolution Ldom 1nm For Setup and Test a comfortable PC Tool is available. For the use in applications with product adapters (e.g. In-Circuit-Tester) optical transfer modules with corresponding light guides are available. This allows for the test of n different products with one system and thereby is an economical solution variant besides the very high number of different products. Technical data: Output of measurement values in x, y, Y Output of dominant wavelength Spectral resolution up to 1nm cyle time appr. 200ms per cycle up to 4 internal calibrations per measurement channel up to 32 user calibrations per measurement channel Calibration for illuminance available for user Synchronized calibration of all channels 8 automatic gain levels Trigger output Systems available for relative and absolute measurement own calibration by customers is possible Highest variety of products – over 1024 independent products and sets of parameters Temperature compensation in the range from 20-55 degree Celsius Win32 Low level DLL Serial and digital interface on board Power supply 12 to 27V DC, max. 0,3A (at 12V) Inputs, signal voltage ON 12 to 27V DC, not potential-free

pageCatalog pdf di En 2012-02-06-10