Single-Phase Filters, Three-Phase Filters, Three-Phase + Neutral Line Filters, DC Filters, Screened Room Filters (3Ph+N) , Output Ferrites, dV/dt Output Filters , Feedthrough Filters
Open the catalog to page 1INTRODUCTION Electromagnetic Interference Most electronic equipment generates electromagnetic interference,which in some cases may be intentional (a radiofrequency generator) or unwanted (electronic motor speed controller). This interference is mainly propagated in two ways, one via an energy conducting network, and the other through the air. These are called CONDUCTED INTERFERENCE (150 KHz TO 30 MHz) and RADIATED INTERFERENCE (30 MHz to 300 MHz), respectively. Also, electronic equipment can fail when working within an electromagnetic environment. This tendency to fail is very common and is known...
Open the catalog to page 2Filter characteristics The filters should cover the range of frequencies between 10 KHz and 300 MHz, although the range can be different depending on the standard to be applied. They should generate high insertion losses within the specified frequency range. The insertion losses should be defined for both SYMMETRIC and ASYMMETRIC modes. As the filters are normally installed in the power supply line, they should comply with the appropiate standards. Special Line Filters In this catalogue it is possible to select power line filters of one or more stages, with printed circuit connection, spade fasterners,...
Open the catalog to page 3INTRODUCTION General Technical Characteristics - Rated voltage single phase: 250 VAC 50/60 Hz - Rated voltage three phase: 520/760 VAC 50/60 Hz - Rated current: The rated current, INOM is given for an ambient temperature the permissible operating current, IPERM, must be reduced according to the follwing formula: - Dielectric strength test: L-N / PE 1850 VAC 3s L/N 1750 VDC 3s - Leakage current: 250 V 50/60 Hz 0.552 x rated for 115 V 50/60 Hz - Climatic category: HPF/HMF - Component tolerance: L: -30%, +50% C: -20%, +20% R: -10%, +10% - Types of connexion: Z = Faston 6,30 x 0,8 mm X = Cables UL-1015...
Open the catalog to page 4EMC Filter Chart by Application
Open the catalog to page 5RAPID GUIDE S Single phase Filters CHASSIS PANEL MOUNTING Medical Use ForSMPS High Atten. Very High Atten. Metal Box Plastic Box ROOM FILTERS SMPS = Switched Mode Power Supply PCB = Printed Circuit Board Single phase Filters Chassis Panel Mounting with I EC Connector Size reduced With Fuses Voltage Selector High Atten. Earth Choke FI-FM FT-M/FTN-M/FTC-M FTCV-M Name Voltage Current Feedthorught Filters Name Voltage Current Topology P Series 250Vac/400 Vdc (10-63 A) Single Line Pi Circuit C Series 250Vac/400 Vdc (10 - 250 A) Single Line C Circuit
Open the catalog to page 6Chassis Panel Mounting Single Phase Filter (1-30 A) General Purpose Chassis mounting single stage filter for general purpose. Good attenuation over a wide frequency range. Small size. General Specifications Maximum operating voltage: 250Vac. Application class: Electrical schematics Product List CY HOUSING LCURRENT CONNECTION Insertion Loss
Open the catalog to page 7High Attenuation Single Phase Filter (1-20 A) General Purpose Double stage filter. High attenuation. General purpose applications with high EMI levels. General Specifications Maximum operating voltage: 250Vac. Application class: Electrical schematics Product List CY HOUSING LCURRENT CONNECTION
Open the catalog to page 8SMPS Chassis Panel Mounting Single Phase Filter (3-10 A) For equipment using s.m.p.s. Chassis mounting double stage filter. High symmetrical attenuation. Switching mode power supplies. General Specifications Maximum operating voltage: 250Vac. Application class: Electrical schematics Product List CY HOUSING LCURRENT CONNECTION Insertion Loss
Open the catalog to page 9High Attenuation Single Phase Filter (1-20 A) General Purpose Chassis mounting single stage filter. General purpose. Good attenuation in a wide frecuency range. General Specifications Maximum operating voltage: 250Vac. Application class: Electrical schematics Product List HOUSING LCURRENT CONNECTION Insertion Loss
Open the catalog to page 10High Attenuation Single Phase Filter (1.30A) General Purpose Chassis mounting single stage filter. High attenuation for noisy circuits. General Specifications Maximum operating voltage: 250Vac. Application class: Product List Electrical schematics HOUSING LCURRENT CONNECTION Insertion Loss
Open the catalog to page 11High Attenuation Chassis Panel Mounting Single Phase Filter for Frequency Inverters (6-30A)_ Electrical schematics For single phase frecuency inverters Double stage filter. Special performance for single phase frecuency Very high asymmetrical attenuation. Product List General Specifications Maximum operating voltage: 250Vac. Hipot test voltage: L/N->PE: 1800Vac2s. L2 R(O) CX CY HOUSING LCURRENT CONNECTION Insertion Loss ASYM
Open the catalog to page 12Very High Attenuation Chassis Panel Mounting Single Electrical schematics General Specifications Maximum operating voltage: 250Vac. Application class: General Purpose Double stage filter. High insertion loss. General purpose filter. Product List HOUSING LCURRENT CONNECTION Insertion Loss
Open the catalog to page 13Single - Phase Filters FFH Very High Attenuation Chassis Panel Mounting Single Phase Filter (1-16A) Electrical schematics General Specifications General Purpose Double stage filter. Very high attenuation (Symmetrical and asymmetrical). For application with high EMI levels. Insertion Loss Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON...
Open the catalog to page 14FFHV Single - Phase Filters Very High Attenuation Chassis Panel Mounting Single Phase Filter for Frequency Inverters (6-30A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. For single phase frequency inverters Double stage filter. Special high performance for single phase frequency inverters. Very high attenuation. Insertion Loss
Open the catalog to page 151 Page
1 Page
1 Page
20 Pages
137 Pages
73 Pages
226 Pages
2 Pages
2 Pages
36 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
3 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
72 Pages
173 Pages
11 Pages
87 Pages
56 Pages
89 Pages
42 Pages
41 Pages
32 Pages
57 Pages
2 Pages
29 Pages
131 Pages
165 Pages
77 Pages