video corpo

Eaton BladeUPS MBM Brochure
2Pages

{{requestButtons}}

Catalog excerpts

Eaton BladeUPS MBM Brochure - 1

Eaton BladeUPS Maintenance Bypass Module (MBM) Features • Three-Breaker Maintenance Bypass • aintenance bypass breaker, rectifier input breaker and UPS M output breaker all rated for 225A @208V (150A @400V) for high availability even as the UPS is serviced • 0 kW N+1 maintenance bypass in just 6U of rack space; 6 matching front bezel blends MBM into existing racks of Eaton® BladeUPS® extended battery modules • nsures correct breaker sequencing during transition to E bypass and return to online • Activate UPS Bypass Mode Switch • ith the press of this single switch the BladeUPS rack is W automatically placed into bypass and the entire system is readied for the transfer of power • Designed to go into top or bottom of the enclosure (rack) • he MBM has three removable conduit landing plates on T the top and bottom of the cabinet to ensure cable entry can be accommodated for raised floor or overhead wiring installations The Eaton BladeUPS Maintenance Bypass Module (MBM) is a fully featured maintenance bypass designed to transfer power from a fully populated 60 kW N+1 BladeUPS system into bypass, allowing maintenance and service to be performed on a de-energized BladeUPS cabinet without affecting power to the critical load. Factory installed 225A @208V (150A @400V) maintenance bypass breaker (MBB), UPS Input Breaker (UIB) and UPS output breaker (UOB). A breaker interlock bar ensures the proper sequencing of the MBB and UOB when bringing the BladeUPS cabinet off and online. The MBM’s Activate UPS Bypass Mode switch simplifies the process of going to bypass even further by providing a single point to transfer all BladeUPS units into bypass, and ready the system for the transfer of power. The MBM is designed to fit seamlessly into your data center environment while occupying minimal space. The 6U housing features front panels designed to mimic the look of BladeUPS EBM extended battery modules (EBMs) so that it will fit aesthetically into your BladeUPS rack. Behind the removable front panels are four LEDs that highlight the current power flow of the system and enhance the safety and security of on-site operators. The MBM also features a shunt trip on the bypass breaker for interfacing with remote emergency power-off (EPO) systems, and all breakers have auxillary contacts (NC and NO available) for breaker on/ off sensing for integration with building control or monitoring systems.

Open the catalog to page 1
Eaton BladeUPS MBM Brochure - 2

Technical specifications environmental specifications general characteristics Type Three-breaker, manual interlock Input & Output Cabling Designed kVA/kW rating Black bezels matching BladeUPS Input/Output ratings 208V Model 103007415-5208 Input Voltage Output Voltage Output Connection Storage Temperature Relative Humidity Audible Noise Less than 50 dBA at 1 meter Input Connection Ambient Temperature electrical ratings 208V Model 103007415-5208 Breaker Frame Trip rating Breaker kAIC rating UL 1778 4th edition IEC 60950-1 edition 1 IEC 62040-1-1 edition 1 Hazardous materials user interface...

Open the catalog to page 2

All Powerware catalogs and technical brochures

  1. Eaton 3S UPS

    2 Pages

  2. 5 series UPS

    8 Pages

  3. TS50

    126 Pages

  4. UPS basics

    8 Pages

  5. Eaton 9PHD

    2 Pages

  6. Eaton 5S

    2 Pages

  7. Eaton 3S UPS

    2 Pages

Archived catalogs