Protection Relay Test Set PW336i
1Pages

{{requestButtons}}

Catalog excerpts

Protection Relay Test Set PW336i - 1

print job table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:20.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Times New Roman", serif; } .font4 { font:9.00pt "Times New Roman", serif; } .font5 { font:18.00pt "Times New Roman", serif; } 6-Current Relay Testing System Model PW336i Spcifications Voltage generators Setting range error < 0.05 % rd.+0.02 % Break capacity ac Vmax: 300Vac /Imax: 4-phase ac( L-N) 4x0~150V rg. typ., at 015A 8A /Pmax: 2000VA 1-phase ac( L-L) 1x0~300V Ranges 15A or 30A Break capacity dc Vmax: 300Vdc /Imax: dc(L-N) 4x0~±150V Resolution 1mA 8A /Pmax: 150W E stortion < 0.05 % typ.(< 0.1 % guar.) Power In-built monitoring and recording 4-phase ac( L-N) 4x60VA at 150V General Monitoring currents and voltage outputs 1-phase ac( L-L) 1x120 VA at 300V B ording analog outputs, binary inputs/outputs status (two generators in series) Frequency Mode real time monitoring, no external wiring is required dc(L-N) 4x40 W at ±150 V Sine signal DC,1~2000Hz Recording length 16s Accuracy ±1ppm Accuracy error < 0.08 % rd.+0.02 % Resolution 0.001 Hz External analog recording unit (optional) Channel : 10 rg. guar., at 0~150 V error < 0.04 % rd.+0.01 % See details of optional accessory AR-10 rg. typ., at 0~150 V Phase Ranges 150V Angle range -360°闗+360° Power supply Resolution 5mV for 150Vac Accuracy <0.05° typ.,<0.1° guar.at 50/60Hz Nominal input voltage 110~240Vac Distortion < 0.05 % typ., (< 0.1 % guar.) Resolution ±0.001° Permissible input voltage 90~260Vac Current generators Auxiliary dc supply Nominal frequency 50/60Hz Permissible frequency 4565Hz Setting range Voltage range 0ח 300V 6-phase AC (L-N) 6x0~15A Power 88W at 110V, 176W at IEC61850 upgrade 3-phase AC (L-N) 3x0~30A 220V, 120W at 300V Interpretation hardware is in-built. Please contact the supplier 1-phase AC (3L-N) 1 x0~90A Accuracy error < 0.1 % rg. typ.(<0.5 % rg. guar.) options to activate the IEC61850 software support fonction dc (L-N) 6x0~±10A Environmental conditions dc( 3L-N) 1x0~±60A Binary inputs Number 8 Operation temperature 0+50°C Power Input characteristics 0~400Vdc threshold or Storage temperature -25ח+70°C 6-phase AC( L-N) 6x150VA it 15A potential free Relative humidity 595% non - condensing 3-phase AC (L-N) 3x240VA at 30A Time resolution 50us EMC (Emission) IEC-61000-3-2/3 1 -phase AC( 3L-N) 1x450VA at 90A Max. measuring time infinite EMC (Immunity) IEC 61000-4-2/3/4/5/6/11 1-phase AC (L-L) 1x450VA !t 30A Debounce/Deglitch time 0~25ms Safety IEC 61010-1 Max compliance Counting fonction < 3kHz at pulse Others voltage (L-N) (L-L) 15Vpk/32Vpk width>150u.s PC connection Ethernet, 10M/100M dc( L-N) 6x100W at ±10A Synchronization control interface Coaxial cable connecter GPS interface RS232 c( 3L-N) 1x480W at ±60A Binary outputs, relay Accuracy error < 0.15 % rd.+0.05 % > imber 4 Ground Socket (earth) 4 mm banana socket; front side Type Potential free relay contacts, Weight 20kg rg. guar., at 0ח15A software controlled Dimensions (W x H x D) 360mm x 157mmx 367 mm POWER ADVANCED TECH. CO., LTD. 2F,4Cell, Tower C, In.Do Mansion,No.48A Zhichun Road, Haidian DistrictBeijing, PR China (100098) Tel. +86 (10) 5873 1010 (reception) Tel. +86 (10) 5873 2512 (direct) Fax. +86 (10) 5873 1816 info@ponovo.com.cn www.ponovo.com.cn

Open the catalog to page 1

All PONOVO POWER CO. catalogs and technical brochures

  1. PW636i

    22 Pages

  2. PW-VP50

    2 Pages

  3. PW636i-F

    21 Pages

  4. PNS630

    6 Pages

  5. NF802

    6 Pages

  6. DC test kit

    2 Pages

  7. RTDS Amplifier

    10 Pages

  8. PONOVO

    44 Pages

  9. STATCOM

    12 Pages

  10. CT Analyzer

    1 Pages

  11. DC test set

    2 Pages