TD4000A Hardware User Manual PONOVO POWER CO., LTD 2F, 4Cell, Tower C, In.Do Mansion No.48A Zhichun Road, Haidian District Beijing, China (Post Code 100098) TEL. +86 (10) 82755151-8887 Office FAX +86 (10) 82755257 E-Mail Info@ponovo.com.cn Website www.ponovo.com.cn TD4000A HARDWARE USER MANUAL VERSION: DATE: TD4000A-AE-1.01 04/06/ 2012 This manual is the publication of PONOVO POWER CO., LTD. Any form of copy needs to be consent by PONOVO POWER CO., LTD. This manual represents the technical status for the moment of publishing. The product information, description and specifications mentioned in the manual do not have any contact binding force and PONOVO POWER CO., LTD remains the right to make modifications to the technical specifications and configurations without prior notice. PONOVO does not take responsibility to the possible error/mistakes in this manual. 1
Open the catalog to page 1TD4000A Hardware User Manual Notes In order to prevent static electricity, the tester must be connected to ground before testing. Please note personal and equipments safety while huge current is putout. Avoid short circuit or connecting load while testing. Avoid external voltage and current being added at the output of equipments. Avoid the equipment being wet by rain. Connect the cables right. Check if the three phase power is complete. The output model should match with control software. No danger exists when A, B power supplies are open circuit. It continues working after over-hot...
Open the catalog to page 2TD4000A Hardware User Manual 1. General Description TD4000A consists of control unit and DC current output unit. The 100-4000A 0.2% high precision programmable DC current is used for characteristics testing in Special high-voltage DC converter station, DC current transformer, control and protection. 2. Panel Description 1) Power outputit supports max.3x3 bus bar connecting in parallel 2) Binary Binary output: 1, relay connection point Binary input: 2, no polarity differences. It can be used to receive protection connection point and milliseconds test, and single or dual channel are...
Open the catalog to page 4TD4000A Hardware User Manual Run lamp: output indicator Over-heat indicator: The lamp alarms and flashes when the temperature of ℃ and out i cut put s . internal power model is above 80 Over load indicator: The lamp flashes when the current and voltage are over-loaded, and manually stops the output. 4) Menu, setting, and adjustment output control unit 5) USB: for reading the report and connecting with PC. 6) Power input: Three-phase four-wire input 7) Power Switch 8) Three phase power indication lamp: the lamp flashes when current input is complete. 5
Open the catalog to page 5TD4000A Hardware User Manual 3. Technical specifications 3.1 Output and Input Model Output range Accuracy TD4000A 0~4000A ±0.1% Port voltage 5.0V Max. output time at full current load 10%-99%raising time 90%-10% falling time 1000A 2000A 4000A Continuous 240s 60s 0A-4000A 20Ms 4000A-0A 10mS DC current table Model DC test range Accuracy 0A~100A 1% TD4000A 100A~500A 0.5% 6 500A~4000A 0.2%
Open the catalog to page 6TD4000A Hardware User Manual 3.2 Binary input The two independent input ports can judge the circuit and space contact is compatible with 30V-250V potential. It is auto identification and time accurate of 1ms0.001-1s ±0.1% 1-999.999s. Figure 1.2 3.3 Binary output One paircontact rating250V DC/0.5A、250V AC / 8A 3.4 LED 4.8 inch High-brightness LCD and visible in glare. 3.5 Power input Rated inputThree-phase four-cable 380V 50Hz, input voltage range: -10%~+20% 50Hz. 7
Open the catalog to page 7TD4000A Hardware User Manual 3. 6 Dimension and weight Dimension660mm x 450mm x 880mmL*W*H Weight110kg 3.7 Env ironmental conditions Temperature: 0℃~40℃ Relative humidity: ≤90% non-condensing Atmospheric pressure: 86kPa~106kPa 8
Open the catalog to page 8TD4000A Hardware User Manual 4. Operation Instructions 4.1 Select test functions There are four buttons F1, F2, F3 and menu in the test unit area. Choose main menu button at any interface to enter the main menu. Entering the main menu, rotate ENTER button to select the test function and push the ENTER go to specified function. Push F1 in sub menu to go back the top menu. 9
Open the catalog to page 9TD4000A Hardware User Manual 4.2 Choose variables Entering the test menu, rotate ENTER button to select variable. The selected operation is displayed in black with background of white. 4.3 Set test parameter Change variable parameter by pushing ENTER button and rotating it clockwise and counterclockwise. Select parameter step by pushing coarse/fine-tuning. The step changes among 0.1,1 and 10. Relative parameters can be set by selecting variable settings before testing. And the parameters cannot be changed during testing. 4.4 Output control Functions of output and stop output can be set by...
Open the catalog to page 10TD4000A Hardware User Manual 4.5 Check and save test report 4.5.1 Check test report The saved test report can be checked by entering the report check interface. Ten reports can be displayed in each page and 30 reports can be stored. “1/3” means that there are three pages and the present is the first page. 4.5.2 Save test report After testing, the present project can be saved through screen tips and test report is saved in the form of date and time. 11
Open the catalog to page 11Buzzer Open F2 Time Setting F2 Time Saving
Open the catalog to page 12TD4000A Hardware User Manual 5. Test functionality instructions In this unit, maximum 4000A can be output manually. The current amplitude and output time can be controlled; the action time can be measured here. The following is the main menu of the set. 13
Open the catalog to page 13TD4000A Hardware User Manual 5.1 Manual test This unit can put out current of 4000A at maximum, which can control current amplitude and output time manually and test opening time. This is the operation interface: Connect the cables as followings: 14
Open the catalog to page 14TD4000A Hardware User Manual Set current and time, and output time will be shown real-timely after run. Iout and Uout will be shown which are the real output current and voltage. The set current will be put out by pushing RUN button and it stops output when getting to the set time. If there is over load, the overheat lamp will give a signal and the system will stop output. There is a period of cooling time which is connected with the present current output time and maximum time is 120s. After cooling, it can go to next output. The equipment needs 30s cooling time after power on, and it...
Open the catalog to page 15All PONOVO POWER CO. catalogs and technical brochures
-
PW-VP50
2 Pages
-
PW636i-F
21 Pages
-
PNS630
6 Pages
-
NF802
6 Pages
-
T200A Universal Tester
1 Pages
-
Protection relay tester
1 Pages
-
Relay test kit
1 Pages
-
Relay tester PW460
1 Pages
-
Protection Relay Test (3I)
1 Pages
-
GPS synchronization signal
1 Pages
-
Protection relay test kit
1 Pages
-
Relay test set PW636i
1 Pages
-
CT Analyzer - PCT200i
6 Pages
-
DC current tester - TD4000
2 Pages
-
Ct analyzer PCT200Ai
1 Pages
-
Digital relay tester NF802
1 Pages
-
Digital relay tester NF801
2 Pages
-
CT Analyzer - PCT200 Series
6 Pages
-
Relay test kit PW336i
1 Pages
-
The relay test system S40A
1 Pages
-
Primary Injection T1000
2 Pages
-
Real Time Simulation Amplifier
10 Pages
-
DC test kit
2 Pages
-
Relay test kit L336i | 6*15A
4 Pages
-
PT CT test kit PCT200 Series
6 Pages
-
Relay test kit POM2 Series
2 Pages
-
Relay test kit L336i
4 Pages
-
Digital relay test set NS601
2 Pages
-
CT Analyzer PCT200 Series
6 Pages
-
CT/PT Test PCT200i
1 Pages
-
Relay test set PW466i
1 Pages
-
Primary Injection Test T1000
1 Pages
-
CT|PT Tester PCT200Ai
1 Pages
-
T1000 Universal Tester
1 Pages
-
Single Phase Relay Kit T200A
1 Pages
-
Protection relay test
4 Pages
-
PONOVO_Products_Catalog
16 Pages
-
Relay test set POM2
2 Pages
-
RTDS Amplifier Brochure
10 Pages
-
PCT200i CT PT Tester
1 Pages
-
Relay test set PW336i
1 Pages
-
CT Analyzer|PCT200Ai
1 Pages
-
CT Analyzer - PCT200i
1 Pages
-
PCT200Ai CT PT Tester
1 Pages
-
PONOVO Products Catalog
16 Pages
-
digital relay testers NS601
2 Pages
-
DC tester | TD4000
2 Pages
-
PONOVO Products | relay tester
16 Pages
-
DC test set | FT3000
2 Pages
-
POM2 Series Relay test set
6 Pages
-
DC tester | 0-4000A
2 Pages
-
Digital relay tester NF801
2 Pages
-
RTDS Amplifier
10 Pages
-
CT/PT testing set
6 Pages
-
Relay test | L336i
4 Pages
-
Relay tester L336i
4 Pages
-
Relay test set POM2
6 Pages
-
Relay test set POM2-3242
1 Pages
-
Relay test L336I
4 Pages
-
PCT200i CT/PTTester | 0-120V
1 Pages
-
Realy test set T1000
1 Pages
-
DC testing equipment TD4000
2 Pages
-
Digital Power Amplifier
10 Pages
-
Universal Relay Teater-L336i
8 Pages
-
PONOVO Relay Template
29 Pages
-
Testing equipment
2 Pages
-
RTDS Amplifier| 3X0~60A RMS
10 Pages
-
Active power filter|APF
6 Pages
-
Protection relay testing set
44 Pages
-
PONOVO
44 Pages
-
SVC|Static VAR Compensator
8 Pages
-
Relay testing device L336i
1 Pages
-
Active power filter
12 Pages
-
STATCOM
12 Pages
-
Static VAR Compensator/SVC
8 Pages
-
Static VAR Compensator
8 Pages
-
PONOVO Relay Test Set
1 Pages
-
CT Analyzer
1 Pages
-
CT Analyzer?PCT 200Ai?
1 Pages
-
Static VAR Compensator?SVC)
8 Pages
-
Static VAR Compensator(SVC)
8 Pages
-
protection relay test set
44 Pages
-
SVC-Static VAR Compensator
8 Pages
-
Protection relay test L336I
3 Pages
-
Relay Teater-L336i
8 Pages
-
Universal Test System POM2
6 Pages
-
Relay Tester S40A&S10A
1 Pages
-
Relay Testing Equipment POM2
6 Pages
-
Digital relay tester pnf801
2 Pages
-
Power relay test set L336i
4 Pages
-
SSCS Type SVC Brochure
8 Pages
-
SVC-Power Quality Control
8 Pages
-
Relay Test Line Catalog - PONOVO
30 Pages
-
Active Power Filter Brochure
12 Pages
-
Power relay tester PW430D
1 Pages
-
DC Converting Station Test
2 Pages
-
DC test set
2 Pages
-
Power relay test set-S100A
1 Pages
-
Power relay test set
2 Pages
-
Relay Test S40/S10
1 Pages
-
Power relay test set S100A
1 Pages
-
Relay Test Set PNF801
2 Pages
-
Relay Test Syetem PW666i
1 Pages
-
Relay Test Set PNS601
1 Pages
-
Protection Relay Test PW433
1 Pages
-
Relay Tester POM2-3243
1 Pages
-
Relay Test Set POM2-6142
1 Pages
-
Real Time Simulation Amplifier
20 Pages
-
Protection relay test sets
44 Pages
-
Protection Relay Test PW460
1 Pages
-
GPRS test seter
1 Pages
-
Real Time Simulation Amplifier
16 Pages