| | | ALL-THE-TIME POWER. OFF-THE-GRID POWER. | | |
| | | |
| | | Low Maintenance: GenSys® requires fewer preventive maintenance calls per year than traditional combustion technologies, lowering your operating costs. Ease and Flexibility of Siting: GenSys provides the freedom to choose your location for optimal user benefits. Rugged Reliability: GenSys systems meet stringent FC1 standards for robust design, construction, operation and quality. Ultra-low Emissions: Fueled by liquid petroleum gas (LPG), GenSys fuel cell systems produce power without combustion. The fuel cell stack produces virtually no emissions, creating only heat and clean water as by-products. Ultra-quiet Operation: GenSys operates with low audible noise (<65dBA at 3 m) in comparison to combustion systems, which typically operate at >75dBA at 3 m, more than 10 times louder. | | |
| | | |
| | | PRODUCT CHARACTERISTICS 6U48 | | |
| | | |
| | | | | | | | | | | | | | | Maximum Continuous Output1 | 6 kW | | | | GenSvs | | Minimum Continuous Output | 1 kW | | | | MVlf wJr w® | Performance: | Adjustable Voltage Output | -46 VDC to -56 VDC | | | | | | | Nominal Operating Range - Voltage | -42 VDC to -60 VDC | | | | | PLUG POWER INC. | | Nominal Operating Range - Current | 18.3 to 110 Amps | | | | | HEADQUARTERS | | Liquid Petroleum Gas (LPG) | GPA HD-5 | | | | | 968 Albany Shaker Road | | Fuel Supply Pressure | .69 bar (10 PSI) | | | | | Latham, New York 12110 | Fuel: | | 0.17 gph @ 1 kW | | | | | Phone: 1.518.782.7700 Fax: 1.518.640.9827 | | Fuel Consumption | 0.33 gph @ 3 kW 0.70 gph @ 6 kW | | | | | | Ambient Temperature | 0°C to 50°C (option to -20°C) | | | | www.plugpower.com | Operation: | Relative Humidity | 5% to 95% non-condensing | | | | | Altitude | 0 m to 2,000 m (6,562 ft) | | | | | | | Dimensions | 1.3mH x .9mW x 1.4mD | | | | | | Physical: | ( 53"H x 36"W x 54.5"D) | | | | | | | Weight | 635 kg (1,400 lbs) | | | | | | CO | <50 ppm | | | | | | NOx | <5 ppm | | | | | Emissions: | SOx | <1 ppm | | | | | | | CO2 | <700 g/kW-hr | | | | | | | Audible Noise | 65 dBA @ 3 m (nominal) | | | | | | | Microprocessor with Diagnostics | Standard | | | | | | Control: | Communications | RS-232 Wireless Modem (Option) Digital From "C" alarm outputs | | | | | | | | | | | | | |
| | | |
| | | 'Rating applies for altitudes up to 300 m (984 ft). Power will decrease above this altitude. Commercial product specifications are subject to change without notice. | | |
| | | |
| | | li PRINTED ON RECYCLED PAPER. | | |
| | | |
| | | | | | | | | | | | | | | |