Output Voltage Range, User Adjustable
|
-48.0 to-55.5 Vdc 1 +24.9 to+27.5 Vdc
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Typical Runtime with Std 6 Cylinder Hydrogen Storage Module (HSM)
|
27 Hours @ 2kW Output Power 11 Hours @ 5kW Output Power
|
|
|
|
|
|
99.95% Purity, Dry, CGA G-5.3 Industrial Grade B
|
|
|
|
|
64 to 110 psig (4.4 to 7.6 bar)
|
|
|
|
|
1.2 scfm (34 slm) or ~3 hrs/cylinder at 3kW output power
|
|
|
|
|
2.2 scfm (63 slm) or ~2 hrs/cylinder at 5kW output power
|
|
|
|
|
|
-40oFto+122oF(-40oCto+50oC) Full Rated Output Power at up to +25C
|
|
|
|
|
Output Power Derated to 4.92kW @ +35oC, 4.85kW @ +45oC & 4.55kW @ +50oC
|
|
|
|
|
|
|
|
|
|
-197 ft to 13,150 ft (-60m to 4000m)
|
|
|
|
|
>1500 ft (457m) Output Power is Derated 75W per 1000 ft (305m)
|
|
|
|
|
Maximum Envelope Dimensions, not including fuel storage
|
46 inches Height x 36 inches Width x 32 inches Depth (117cm H x 91cm Wx 81cm D)
|
|
|
|
|
|
|
|
|
|
|
|
FCC Class A, CSA (ANSI FC-1), CE and NEBS Level 3
|
|
|
|
|
|
Nominal: 0.53 gph (2.0 lph) Max: 1.1 gph (4.2 lph)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pad Shear, Water Intrusion, Tampering
|
|
|
|
|
|
|
|
|
|
|
|
Programmable Start Voltage Range
|
-48.0V to -55.0Vdc +24.9V to +27.0Vdc
|
|
|
|
|
|
|
|
|
|
RS-232C & USB Included, Modem & Ethernet/IP Optional
|
|
|
|
|
Graphical Service Interface provides status, event log & control
of unit via laptop PC (not included)
|
|
|
|
|
|
"Low Fuel", "Minor Alarm", "Major Alarm" & "Fuel Cell Running" all Included
|
|
|
|
|
|
|
|