You may also be interested in
Communication software, Controller, Rotary damper, Coupling, Stepper motor controller
Text version of the page
Power Stages
A 32-48 MINI
Plug-in Stepper Motor Power Stage
in Minirack Size
Technical Information
Plug-in stepper motor power stage
For bipolar control of
2-phase stepper motors
Step resolution up to 1/512 mini step
5 V push-pull inputs,
electrically separated by optocoupler:
control pulses, direction, boost, activation
Electronic monitoring
of overtemperature, short circuit and low
voltage
Status LED
Reset button
Motor current up to 3.5 APEAK
Supply voltage 24 to 48 VDC
Operation parameter programming by
setting switches or at the PC via
ServiceBus
Run current setting switch:
15 increments
Step resolution and preferred motor
direction setting switch:
full step to 1/20 step
ServiceBus for configuration by
PC software (included in delivery)
ServiceBus-Comm for Windows®
Size 60 x 116 x 20 mm
Adapted for mounting in a type MR 8
minirack
Fig. 1
The A 32-48 MINI Power Stage
A 32-48 MINI is a stepper motor power stage
for bipolar control of 2-phase stepper motors up
to 3.5 APEAK phase current.
The precision current control of the A 32-48
MINI according to the patented SYNCHROCHOP
principle effects optimum running
performance of the stepper motor.
The phase current and step resolution setting
switches are placed above the connectors for
wiring the stepper motor and I/O signals.
Via RS 485 connection, the power stages can
be configurated by PC in the ServiceBus mode.
ServiceBus is active when all setting switches
of all power stages in a minirack are set to 0.
The 24 to 48 VDC supply voltage and a 5 VDC
logic supply voltage have to be connected to
the rear 48-pole connector.
Connections to the ServiceBus and address
leads for defining the device address during
bus operation are also placed on the 48-pole
connector.
The ServiceBus was designed for communica-
tion with the power stage via RS 4851 port or
USB port (when operating the A 32-48 MINI
power stage in a MR 8 minirack).
All settings are done by PC with the phytron
ServiceBus-Comm software. Alternatively, the
instructions can be implemented into the
customer's own environment: ASCII strings in
readable characters – e. g. with LabVIEW,
HyperTerminal or in C. This way, parameters
can be easily transmitted to the power stage
during initialising or exchanging components;
status information can be evaluated.
In the ServiceBus mode, run, stop and boost
current are programmable in 10 mA increments
independently of each other.
The step resolution – full step up to 1/20 step –
can be set to values up to to 1/512 step in the
ServiceBus mode in order to improve the motor
run behavior. The step accuracy is maximum
1/20 step.
The current delay time is set to 40 ms in the
setting switch mode. This value can be
changed in the ServiceBus mode.
1The PC is bus master and requires a type RS 422
or RS 485/4-wire port.
ServiceBus Mode
Controls and Connections
Heat sink
LED
Power On / Error
Reset button
Run current
Setting switch
Step resolution
Setting switch
Push-pull inputs
Controle pulse
Direction
Boost
Activation
Stepper motor
Connection
48-pole
Connector
48 VDC supply voltage
5 VDC logic supply voltage
RS 485 for ServiceBus
Error output
A32-48 MINI / 07-2 GB
|
|