PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it Web: www.petrosystem.it APPLICATIONS Water-In-Oil Analyzers For Ships and Naval Flow sensors and water level sensors makes it possible to accurately monitor water in oil contamination in any oil process onboard vessels including lubrication oil, hydraulic oil and any type of engine fuel. Water in oil can cause costly breakdowns totaling hundreds of thousands of dollars in lost revenue. It is impossible to escape the problems of water contamination in oil systems. Recently there have been initiatives to determine the feasibility of extending the life of oils or determination of oil change period by analyzing them for water content using an online water-in-oil analyzer. Online measurement of many types of hydraulic oils, lubrication oil and fuel oils , diesel etc. by the EASZ-1 water in hydraulic oil analyzer, reduces the need for a laboratory to analyze the water content of oil samples. It also acts as an added guarantee because water in oil is continuously being measured online. In addition, the water-in-oil analyzer can be tested onsite or in a laboratory setting for further accuracy and verification against a Karl Fischer coulometric titrator in determining water content in oil. Many clients and organizations have taken the lead as a part of an ongoing effort to elim inate waste and reduce pollution have been looking for a way of extending the operational life of transmission and hydraulic oils, determining fuel quality for engines and reducing the risk of breakdown from water contamination in lubrication systems. Implementation of an effective oil extension and monitoring program needs some thought. In some cases for e.g with high speed purifying systems, the ability to perform accurate water content analysis in a factory or a fleet would allow purified oil to be returned to service more quickly. The EASZ-1 is a unique and affordable accurate online water in oil detector. It can measure as low as ppm and percentages of water including free water. Some application requires more thought and logic. This is because of problems encountered with high water content at start up of the purifier system. This high water content needs to be monitored without total destruction to the moisture sensor. Unfortunately, most moisture sensors cannot be used once they have been contaminated with free water, they simply stop functioning. The EASZ-1 will measure very low ppm levels of moisture contamination (dissolved water in oil) and extremely high water content with no damage possible to its water sensing element. It is important to address the problems encountered onboard a vessel that has decided to install the EASZ-1 water in oil sensor for e,.g onto a Diesel Generator Lube Oil Purifier Outlet. A robust and reliable Water Content Alarm System for a typical Engine Lubrication System application requires some logic. This logic can be engineered either by ship system integrators or provided as a total water in oil monitoring package supplied by. A typical example would be the a total solution system to solve the problems encountered onboard a vessel after installing the first EASZ-1 onto the Diesel Generator Lube Oil Purifier Outlet. Typically a problem encountered (alarm triggering during startup sequence and purifier desludge cycle) can be resolved confidently using the EASZ-R3, a display and logic device capable of taking on up to 4 EASZ-1 Water-In-Oil Monitors with required functionality. Instead of only one EASZ-1 standard water in oil monitor display for each point monitored, the more advanced EASZ-R3 can take on both monitoring points in question (Diesel Generator and Main Engine, hydraulics, other lubrication systems and fuel), so only one unit is needed.

Open the catalog to page 1
Oil Centrifuge/Purifier Monitor - 2

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it Web: www.petrosystem.it Here is an example of a complete system monitoring 2 Purifiers. System Description Monitoring Points: ? Diesel Generator Lube Oil Purifier Outlet ? Main Engine Lube Oil Purifier Outlet Requirement: Monitor Water Content after Purifier(s) and provide a dry contact alarm. • Ability to set hysteresis for increased water content levels to avoid alarm for spurious short lived increase in water content. • Ability to disable dry...

Open the catalog to page 2
Oil Centrifuge/Purifier Monitor - 3

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it Web: www.petrosystem.it Fig 2. EASZ-R3 PLC system for up to 4 each EASZ-1 water in oil monitors Fig 3.0 schematics/control logic for water in oil system

Open the catalog to page 3
Oil Centrifuge/Purifier Monitor - 4

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it Web: www.petrosystem.it Electrical Connections: A multicore signal cable to be used to bring Valve Status, Alarm Point and RunMode from Purifier 1 and Purifier 2 into the EASZ-R3. EASZ-R3 can be mounted in cabinet for Purifier 1 alternative Purifier 2, or if so is desired in any other location. It is possible to mount EASZ-R3 in one of the Purifier Cabinet doors, alternatively on a piece of DIN rail inside one of the cabinets.

Open the catalog to page 4
Oil Centrifuge/Purifier Monitor - 5

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it Web: www.petrosystem.it The EASZ-1 water in oil monitor is not limited to fleet applications. The sensors can also be retrofitted to existing applications including: ? Verification of Desorber performance ? Verification of Purifier performance ? Aviation Hydraulics ? Aviation Fuel ? Reduction Gears ? Stern tube bearing lubrication system ? Oil contamination warning system for trucks transporting oil ? Bow Thruster - Gear Oil ? Cement Mill - Gear...

Open the catalog to page 5
Oil Centrifuge/Purifier Monitor - 6

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it Web: www.petrosystem.it ? Mobile Equipment - Container Straddler - Fine Filter ? Mobile Filtration ? Paper Mill Lubricating System, ? Plastic Injection Moulding Machine - Hydraulic System ? Plastic Injection Moulding Machines - Hydraulics ? Quench Oil System ? Quench Oil ? Verification of Vacuum dehydrator performance ? Verification of oil filter performance ? Reduction Gears ? Wall Ironing Machines, Lubrication Oil ? Water Jet - Hydraulic System ?...

Open the catalog to page 6

All PETROSYSTEM catalogs and technical brochures

  1. Air Bags

    2 Pages

  2. NYLON PLUG

    3 Pages

  3. PIGS

    13 Pages

  4. OMNI PIG

    2 Pages

  5. FOAM PIGS

    2 Pages

Archived catalogs

  1. DENDi SERIES

    1 Pages

  2. DC-40 SERIES

    1 Pages

  3. FOAM PIGS PE

    2 Pages

  4. CB-6

    8 Pages