| | | | UC2000-30GM-E6R2-V15 | UC2000-30GM-E7R2-V15 | UC2000-30GM-IUR2-V15 | |
| | Sensing range | 80 ... 2000 mm | | ♦ | ♦ | |
| | Transducer frequency | approx. 180 kHz | ... | |
| | Adjustment range | 120 ... 2000 mm | ♦ | ♦ | ♦ | |
| | Unusable area | 0 ... 80 mm | | |
| | Operating voltage | 10 ... 30 V DC , ripple 10 %SS | ♦ | ♦ | ♦ | |
| | No-load supply current | < 50 mA | ♦♦ | | |
| | Power consumption | < 900 mW | | |
| | Output type | 1 current output 4 ... 20 mA 1 voltage output 0 ... 10 V | | | ♦ | |
| | 2 switch outputs npn, NO/NC, parametersabe | ♦ | | |
| | | 2 switch outputs pnp, NO/NC, parameterisabe | ♦ | | | |
| | Rated operational current | 200 mA , short-circuit/overload protected | ♦ | ♦ | | |
| | Switching frequency | < 25 Hz | ♦♦ | | |
| | Deviation of the characteristic curve | < 02 % of full-scale value | | |
| | Resolution | evaluation range [mm]/4000, but > 0.35 mm | | | ♦ | |
| | Synchronisation | bi-directional 0 leve -UB...+1 V 1 leve: +4 V...+Ub input impedance: > 12 KOhm synchronisation pulse: > 100 ^s, synchronisation interpulse period: > 2 ms | ♦ | ♦ | ♦ | |
| | Synchronisation frequency | |
| | Common mode operation | < 30 Hz | ♦ | ♦ | ♦ | |
| | Multiplex operation | | ♦♦♦ | |
| | Interface type | RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit | ♦ | ♦ | ♦ | |
| | Ambient temperature | -25 ... 70 °C (248 ... 343 K) | ♦♦♦ | |
| | Protection degree | IP65 | ♦ | ♦ | ♦ | |
| | Connection | | | |
| | Materia | | | | | |
| | Housing | stainless steel 1.4303 plastic parts PBT | | |
| | Transducer | | ♦ | ♦ | ♦ | |
| | Mass | 140 g | ♦♦ | | |
| | 170 g | | |
| | | | | | | |