| | | | TopScan-S-M/L310 | TopScan-S-M2S/L750 | TopScan-S-M3S/L900 | TopScan-S-M5S/L1400 | |
| | Detection range min. | 0 ... 1500 mm | | ♦ | ♦ | ♦ | |
| | Detection range max. | 0 ... 2500 mm | | |
| | Light source | IRED | ♦ | ♦ | ♦ | ♦ | |
| | Black/White difference (6 %/90 %) | < 2 % at 2000 mm sensor range | | |
| | Marking | CE | ♦ | ♦ | ♦ | ♦ | |
| | Number of beams | (number of built-in sensor modules AIR 16) | 13 4 6 | |
| | Operating mode | Background evaluation | ♦ | ♦ | ♦ | ♦ | |
| | Diameter of the light spot | 3 cm x 8 cm at 2000 mm sensor range | ♦♦♦♦ | |
| | | | ♦ | ♦ | ♦ | ♦ | |
| | | sensing range adjuster | ♦♦♦♦ | |
| | Operating voltage | 24 V DC +/- 20 % | ♦ | ♦ | ♦ | ♦ | |
| | No-load supply current | | 65 mA | 175 mA | 230 mA | 340 mA | |
| | Test input | active at U = 11 V DC at 30 V DC inactive at U = -3 V DC at 5 V DC | ♦ | ♦ | ♦ | ♦ | |
| | Switching type | Relay de-energized at object inside the scanning range | ♦♦♦♦ | |
| | Signal output | Relay, 1 alternator | ♦ | ♦ | ♦ | ♦ | |
| | Switching voltage | < 250 V AC/DC | ♦♦♦♦ | |
| | Switching current | < 1 A | ♦ | ♦ | ♦ | ♦ | |
| | Response time | < 70 ms | ♦♦♦♦ | |
| | Standards | EN 60947-5-2 | ♦ | ♦ | ♦ | ♦ | |
| | Standards 2 | EN 61000-6-2 without EN 61000-4-5, EN 61000-4-11 | ♦♦♦♦ | |
| | Standards 3 | EN 61000-6-3 | ♦ | ♦ | ♦ | ♦ | |
| | Standards 4 | DIN 18650 | | ♦♦♦ | |
| | Standards 5 | EN 12978 | ♦ | ♦ | ♦ | ♦ | |
| | Ambient temperature | -10 ... 50 °C (263 ... 323 K) | ♦♦♦♦ | |
| | Length of housing L | | 310 mm | 750 mm | 900 mm | 1400 mm | |
| | Mounting height | max. 2500 mm | ♦♦♦♦ | |
| | Protection degree | | ♦ | ♦ | ♦ | ♦ | |
| | Connection | screw terminals | ♦♦♦♦ | |
| | Housing | aluminium / ABS | ♦ | ♦ | ♦ | ♦ | |
| | Optical face | PMMA | ♦♦♦♦ | |
| | | | | | | | |