IPH-L2-V1 Read/write head
Dimensions
M12x1 7 67 LED green
LED yellowLED greenLED yellow 40 40 20 31 Model Number
46 ø 5,5 608 IPH-L2-V1 Read/write headfor IDENT Control
Technical data
General specifications
Operating frequency 125 kHzTransfer rate 2 kBit/s >
Features
•VariKont L
(r) Type with variable alignment capability in 15° steps and front face in 90° steps•4 x dual LEDs on the corners for visibility on all sides•Protection degree IP67
•Connection via plug connection V1 (M12x1)
Operating distance maximum: 80 mm >
Indicators/operating means
LED green/yellow green: power ongreen flashing: read/write attempt performedyellow: data carrier detected >
Electrical specifications
Power consumption P >
1,2 WSupply from the IDENT Control >
Compliance with standards and directives
Directive conformity R&TTE Directive 1995/5/EC EN 301489-1, EN 301489-3, EN 300330-2, EN 60950-1Standard conformity Electromagnetic compatibility EN 61326Protection degree EN60529 >
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K) Storage temperature -40 ... 85 °C (233 ... 358 K) >
Mechanical specifications
Protection degree IP67Connection plug connector M12 x 1 Material Housing PA-GF35 Encapsulation compound FermadurInstallation not embeddable in metal Distance between two heads Multiplex on: 60 mm Multiplex off: 450 mmMass approx. 210 g >
1423 +A
-
B1234 Shield Date of issue 2005-08-18 - Catalogue Identification Systems 2005/2006 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com