IPH-F61-V1 Read/write head
Dimensions
M12 x 1 6.5520.83.6 12 ø 26 Ground connection 28 14 76.4ø 4.4
ø 27 Model Number Technical data
IPH-F61-V1
General specifications
Read/write headfor IDENT Control
Operating frequency 125 kHzTransfer rate 2 kBit/s Operating distance maximum: 70 mm >
Electrical specifications
Power consumption P >
Features
1,2 WSupply from the IDENT Control >
•Particularly flat construction•Connection cable with V1 plug (M12x1)•Protection degree IP67
•Can be mounted on metal
Compliance with standards and directives
Directive conformity R&TTE Directive 1995/5/EC EN 301489-1, EN 301489-3, EN 300330-2, EN 60950-1Standard conformity Electromagnetic compatibility EN 61326Protection degree EN60529 >
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K) Storage temperature -40 ... 85 °C (233 ... 358 K) >
Mechanical specifications
Protection degree IP67Connection plug connector M12 x 1 Material Housing ABS Encapsulation compound CY 221/HY 2966Installation Distance between two heads Multiplex on: 50 mm Multiplex off: 290 mmMass approx. 50 g Cable length 20 cm >
1423 +A
-
B12
3
4 Shield Date of issue 2005-08-18 - Catalogue Identification Systems 2005/2006 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in Germany 34