Text version of the page
8Information
8.1Protection class provided by housing
(DIN VDE 0470 Part 1, EN 60529) >
IP 6 7
Degree of protection against contact and foreign bodies Degree of protection against water0- Not protected0- Not protected 1-Protection against access to hazardous parts with the back of the hand-Protection against foreign bodies with adiameter of 50 mm and greater 1-Protection against dripping water2- Protection against access to hazardous partswith one finger-Protection against foreign bodies with a diameter of12.5 mm and greater2-Protection against dripping water if the housingis inclined up to 15° 3-Protection against access to hazardous partswith a tool-Protection against fixed foreign bodies with diameters of 2.5 mm and greater 3-Protection against sprayed water4-Protection against access to hazardous parts with a wire-Protection against foreign bodies with adiameter of 1.0 mm and greater4-Protection against splash water 5-Protection against access to hazardous partswith a wire -Dustproof 5-Protection against water jets6-Protection against access to hazardous partswith a wire-Protection against dust6-Protection against strong water jets 7-Protection against temporary submersion in water8-Protection against continuous submersion in water 9-Protection against water in high pressure/steam jet cleaning >
Notes:Wherever an identifying number does not need to be specified, it is replaced by "X".Devices that are designated with the second figure 7 or 8 do not need to fulfil the requirements of the second figures 5 or 6 unless they have been given a double designation (for example IPX6/IPX7).
Issue date 2005-08-18 - Catalogue Identification Systems 2005/2006 194
Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in German y Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.co m