VAG-MOD-KF-R4AS-Interface professional gateway Technical data Function

General specifications

The VAG-MOD-KF-R4 is a MODBUS gate-way with PLC MANUFACTURERS functionality. The design of thismaster is ideal for use in a industrial cabinet.Its hous- ing, only 60mm wide, occupies little space ina cabinet installation. The VAG-MOD-KF-R4is installed by snapping it onto the 35mmDIN Rail according to EN50022, with theintegrated Power Rail. The AS-Interface sig-nal is transmitted via conductors, which areintegrated in the Power Rail. Thus all cabinetmodules in KF housing can be connected tothe AS-Interface cable by simply snapping them onto the DIN Rail. The AS-Interfacedata can be accessed in a binary format(functions 1, 2, 5 and 15), or through the reg-isters (functions 3, 4, 6 and 16). MODBUSdiagnostic registers are supported.The AS-Interface data can be used in variousways. Important data is available eitherpacked or unpacked by means of the regis-ters or in the binary format. Thus the AS- Interface masters with MODBUS slave inter-face can be accessed by different MODBUSmasters and do not require large-scale adap- tations. Power to the master is supplied bythe AS-Interface cable.Two push buttons are used for addressassignment of the AS-Interface slaves andacceptance of the desired configuration. Inconfiguration mode, all detected AS-Interfaceslaves are displayed on the 2-digit LCD. Innormal operation, the LCD is blank unlessthe master detects a faulty AS-Interfaceslave. There are 7LEDs on the front panel,showing the current status of the AS-Inter-face line.

AS-Interface specification V2.0
Indicators/operating means
LC display, two-digit address display, error messageLED BUS ACTIVE MODBUS interface in operation, LED green
Masters and GatewaysPower Supplies, Extender, RepeatersSafety at workI/O ModulesControl cabinetI/O ModulesField applicationAnalogue modulesOther modulesInductive sensorsPhotoelectric sensorsRotary encodersAccessories LED AS-i ACTIVE AS-Interface operation normal; LED greenLED CONFIG ERR configuration error; LED red LED PRG ENABLE autom. programming; LED greenLED ENERGY voltage ON; LED green LED PRG MODE projecting mode active; LED yellowLED U AS-i AS-Interface voltage; LED green Switch SET Selection and setting of a slave addressButton MODE Mode selection/save configuration
Electrical specifications
Insulation voltage U
i 500 V Rated operational voltage U
e from AS-InterfaceRated operational current I
e 200 mA
Interface
Protocol MODBUS Interface type RS 485
Connection
AS-Interface removable coded terminals, Power RailMODBUS RS 485 interface
Ambient conditions
Ambient temperature 0 ... 55 °C (273 ... 328 K) Storage temperature -15 ... 70 °C (258 ... 343 K)
Mechanical specifications
Protection degree IP20Mass 420 g

PLC Functionality

Professional software

The VAG-MOD-KF-R4 has 16kBytes of pro-gram memory, 8kBytes of main memory,1024counters and 1024timers for the PLCfunctionality. These capacities suffice toprocess data on the AS-Interface. Thus the master can also be operated in "stand-alone"mode. The program processing time is 2msper 1000word commands. The programming language is based on the STEP5 The AS-i Control Tools software is supplied as restricted version together with the documen-tation. The software performs addressing, programming and monitoring of the AS-Interfacenetwork. In addition, it contains an editor that creates programs for the integrated PLC func-tionality. The full version of the AS-i Control Tool is available as an accessory and features an expanded diagnostics professional monitor as well as a larger program memory for AS-Interface Controlwhich makes it possible to detect faulty telegrams of slaves. program-ming language.

Accessories

VAZ-SW-ACT32 Full version of the AS-i Control Tools VAZ-R4-R2 RS232C/RS485 industrial converter UPR-E End cap for UPR-03 und UPR-05 UPR-05 Universal Power Rail with DIN rail and cover, 5 leads

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in German y

Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.co m

47

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-356
pdf-page pdf di En 2008-12-49-05