VBA-4E-G4-Pt100AS-Interface analogue module Technical data Function
Indicators/operating means
The VBA-4E-G4-Pt100 analogue modulehas four analogue inputs for Pt100 RTDs.The asynchronous transformation of meas-
ured values and the data transfer is accom-plished in accordance with AS-Interfaceprofile7.3. The resolution of the analoguevalues is 16bit or 0.1°C. System distur-bances are eliminated using a programmablefilter (50Hz/60Hz).The IP65 rated G4 module is especially suit-able for use in hazardous environments.Connection to the measured-value transmit-
ters is established by means of cable glandsand cage tension professional spring terminals thus mak-ing the installation especially user-friendly.For pre-addressing the module, it can beplugged directly onto the adapter of thehand-held programming device VBP-HH1.Various bases are available for the module.Use the U-G1F base to connect to the AS-Interface flat wire, and the U-G1P base to
connect to the round cable. The bases can,at the same time, be used as IP67 rated dis-tributor box. Moreover, they both have two
connection possibilities for AS-Interfacecables.Output modules often have to be mounted inseries with input modules. The outputs of theoutput modules are supplied externally withpower. If the power is supplied via a flatcable, the power cable has to be mounted inthe base of the input module. The U-G1FFbase should be used in this case. The VBA-4E-G4-Pt100 then uses the AS-Interfacecable instead of the power cable.
LED FAULT error display; LED redred: communication errorred flashing: periphery faultLED PWR AS-Interface voltage; LED green >
Masters and GatewaysPower Supplies, Extender, RepeatersSafety at workI/O ModulesControl cabinetI/O ModulesField application LED ANALOG status of input signal; LED greenoff: not connected (periphery fault)green: signal within measurement rangegreen flashing: signal outside of measurement range (periph-ery fault) >
Electrical specifications
Protection class IIIRated operational voltage U >
e 26.5 ... 31.6 V from AS-Interface Rated operational current I >
e 80 mA >
Input
Number/Type 4 inputs for Pt100, 2- or 3-wire connectionSupply from AS-Interface Resolution 16 Bit / 0.1 °C >
Programming instructions
Profile S-7.3.EIO code 7 ID code 3ID2 code E Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i) function P0 mains power frequency filterP0=1, 50 Hz
professional filter activeP0=0, 60 Hz filter activeP1/P2 Communication of the peripheral fault on measuring channels 1 to 4: >
P1P21234
00 ✓ –––01 ✓✓ ––10 ✓✓✓ –11 ✓✓✓✓ P3 configuration Pt100
P3=1, 2-wire connection
P3=0, 3-wire connection >
Accessories
Ambient conditions
VBP-HH1
Analogue modulesOther modulesInductive sensorsPhotoelectric sensorsRotary encodersAccessories Ambient temperature 0 ... 70 °C (273 ... 343 K)Storage temperature -25 ... 85 °C (248 ... 358 K) >
Hand-held programming device
Mechanical specifications
VAZ-G4-B
Protection degree IP65 according to EN 60529 >
Blind plug PG7
Connection cable piercing method or terminal compartmentflat cable yellow or standard round cableinputs: screwed connection M12x1,5 and cage-clamp termi-
nalsMass 350 g >
Matching system components
U-G1F Base for connection to flat cable (EMS; AS-Interface only)
Mounting DIN rail >
U-G1FA Base with addressing professional jack for connection to flat cable (EMS; AS-Interface only) U-G1P Base for connection to round cable (EMS;
AS-Interface only)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in German y Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.co m