VBA-4E3A-G4-ZE/E2AS-Interface sensor-/actuator module Technical data Function

General specifications

The VBA-4E3A-G4-ZE/E2 is an AS-Interfacecoupling module with four inputs and threeoutputs. Mechanical contacts and 2- and 3- wire sensors can be connected to the inputs.The sensors are supplied via the module.The outputs are electronic outputs, whichcan be loaded to 24VDC and 2A or 1.5Aper output (total load <4A).The G4 module is especially suitable forrough conditions. Sensors and actuatorsattach to manufacturers of cable glands and cage tensionspring terminals thus making the installation especially user-friendly. For pre-addressingthe module it can be plugged directly ontothe adapter of the hand-held programmingdevice VBP-HH1.The current switching state of each channelis indicated by an LED, located on the mod-ule's top side. In the case of communicationerrors on the bus, the outputs are de-ener-gised via an integrated watchdog. Both flat and round professional cables can be used forthe AS-Interface transmission line and theexternal 24VDC power supply manufacturers. Use the U-G1FF base for the AS-Interface flat cable.The AS-Interface standardised EEMS inter-face, uses the cable piercing method to con-nect both the yellow and black flat wires.Use the U-G1PP base for the round cable.The AS-Interface-cable as well as the exter-nal power supply may be connected withinthis base.

Slave type A/B slave
Indicators/operating means
LED PWR/FAULT dual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supplyLED AUX ext. auxiliary voltage U
Masters and GatewaysPower Supplies, Extender, RepeatersSafety at workI/O ModulesControl professional cabinet AUX ; LED green LED IN switching state (input); 4 LED yellowLED OUT switching state (output); 3 LED yellow
Electrical specifications
Auxiliary voltage (output) U
AUX 24 V DC ± 15 % PELV Protection class IIIRated operational voltage U
e 26.5 ... 31.6 V from AS-Interface Rated operational current I
e 60 mA (without sensors) / max. 240 mA
Input
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DCSupply from AS-Interface Voltage 21 ... 31 VCurrent loading capacity 180 mA (T
B 40 °C), 140 mA (T
B 60 °C), short-circuit proof Input current 8 mA (limited internally)Switching point according to DIN EN 61131-2 (Type 2) 0 (unattenuated) 2 mA1 (attenuated) 4 mA
Output
Number/Type 3 electronic outputs, PNP

Note:

Supply from external auxiliary voltage U

The device incorporates communicationmonitoring, which switches off power to theoutputs if no communication has taken placeon the AS-Interface line for longer than40ms.An overloading of the internal input supply orof the outputs is signalled to the AS-Interfacemaster via the "Peripheral fault" function.Communication via the AS-Interface remains intact.

AUX Current 4 A totalOUT 1, OUT 2: 2A per output OUT 3: 1.5A Voltage (U
AUX - 0,5 V)
I/O ModulesField applicationAnalogue modulesOther modulesInductive sensorsPhotoelectric sensorsRotary encodersAccessories
Programming instructions
Profile S-7.A.0IO code 7 ID code AID1 code 7 ID2 code Data bits (function via AS-Interface) inputoutput D0 IN1OUT1D1 IN2OUT2 D2 IN3OUT3D3 IN4- Parameter bits (programmable via AS-i) functionP0 not used P1 not usedP2 not used

Accessories

P3 not used
Ambient conditions

VBP-HH1

Ambient temperature -25 ... 60 °C (248 ... 333 K)Storage temperature -25 ... 85 °C (248 ... 358 K)

Hand-held programming device VAZ-G4-B

Mechanical specifications

Blind plug PG7

Protection degree IP65 according to EN 60529 Connection cable piercing method or terminal compartmentflat cable yellow/flat cable black or standard round cableinputs/outputs: screwed connection M12x1,5 and cage workholding terminalsMass 350 g

Matching system components

U-G1FF Base for connection to flat cable (EEMS; AS-Interface and external auxiliary pow- er)

Mounting DIN rail or screw mounting

U-G1FFA Base with addressing professional jack for connection to flat cable (EEMS; AS-Interface and ex-ternal auxiliary power) U-G1PP Base for connection to round cable (EEMS; AS-Interface and external auxiliary volt-age)

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in Germany

Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com

171

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 151 p.151
page 152 p.152
page 153 p.153
page 154 p.154
page 155 p.155
page 156 p.156
page 157 p.157
page 158 p.158
page 159 p.159
page 160 p.160
page 161 p.161
page 162 p.162
page 163 p.163
page 164 p.164
page 165 p.165
page 166 p.166
page 167 p.167
page 168 p.168
page 169 p.169
page 170 p.170
page 171 p.171
page 172 p.172
page 173 p.173
page 174 p.174
page 175 p.175
page 176 p.176
page 177 p.177
page 178 p.178
page 179 p.179
page 180 p.180
page 181 p.181
page 182 p.182
page 183 p.183
page 184 p.184
page 185 p.185
page 186 p.186
page 187 p.187
page 188 p.188
page 189 p.189
page 190 p.190
page 191 p.191
page 192 p.192
page 193 p.193
page 194 p.194
page 195 p.195
page 196 p.196
page 197 p.197
page 198 p.198
page 199 p.199
page 200 p.200
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-356
pdf-page pdf di En 2008-12-49-05