VAA-4E4A-KE-ZE/RAS-Interface sensor-/actuator module
Mechanical specifications
Protection degree IP20 according to EN 60529 Connection removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25mm >
2 2 Masters and GatewaysPower Supplies, Extender, RepeatersSafety at work ...2.5mm for multiple-wire connection with two wires of equal cross-sec-tion:flexible with twin wire-end ferrules: 0.5mm >
2 ...1.5mm >
2 Mass 170 g Mounting DIN rail >
Notes
Installation, commissioning, maintenance: The device has to be installed into a separate electrical operation facility with access only forelectrical professionals or instructed persons.Connectors manufacturer with dangerous contact voltage must only be plugged-in or unplugged in a de-
energized state.The rights, guidelines and standards according to the intended or planned use should beobserved. Bundled devices: Isolation to external surfaces: basic insulation to EN60947-1, no basic insulation at the termi-nals.
I/O ModulesControl cabinetI/O ModulesField applicationAnalogue modulesOther modulesInductive sensorsPhotoelectric sensorsRotary encodersAccessories Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in German y 140
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.co m