VBA-4E3A-KE-ZE/RAS-Interface sensor-/actuator module Technical data Function

General specifications

The AS-Interface VBA-4E3A-KE-ZE/R I/Omodule is a switch industrial cabinet module with4inputs and 3relay outputs. The housing, only 22.5mm in width, takes up little place inthe switch cabinet. The VBA-4E3A-KE-ZE/Rcan be mounted by snapping it onto the35mm carrier rail in accordance withEN50022.Plug-in terminals are used for connection. 4Xterminal blocks (black) are used for theinputs. Double terminal blocks manufacturers (red outputs,yellow AS-Interface) are used to connect out- puts and the AS-Interface. This makes it pos-sible to separate individual actuators suppliers or tosupply power during commissioning or serv-icing.Either the module (from the AS-Interface) oran external power source are used to supplypower to the inputs and the connected sen-sors. One switch in the device is used forswitching. The selection of the internal input professional power supply is displayed on the INT LED.An LED on the front control plate is used todisplay the current switching state for each input and output.

Slave type A/B slave
Indicators/operating means
LED FAULT Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supplyLED INT Internal input voltage active; LED green
Masters and GatewaysPower Supplies, Extender, RepeatersSafety at work LED PWR AS-Interface voltage; LED greenLED IN switching state (input); 4 LED yellow LED OUT switching state (output); 3 LED yellow
Electrical specifications
Auxiliary voltage (input) U
EXT 12 ... 30 V DC PELVRated operational voltage U
e 26.5 ... 31.6 V from AS-Interface Rated operational current I
e 35 mA (without sensors) / max. 190 mAOvervoltage protection O1 ... O3: Over voltage category IIU
EXT , U
e : Over voltage category III, safe isolated power sup-plies (PELV)
Input
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC Supply from AS-Interface (switch position INT, basic setting) or exter-nal U

Note:

EXT (switch position EXT)Voltage 21 ... 31 V DC (INT)

The device is equipped with communicationmonitoring that turns off the outputs if no AS-Interface communication has taken placewith the device for more than 40ms. An overload of the internal input supply isreported by the 'periphery error' to the AS-Interface master. Communication over theAS-Interface remains in effect.

Current loading capacity 150 mA, overload- and short-circuit proof (INT)Input current 8 mA (limited internally) Switching point according to DIN EN 61131-2 (Type 2)0 (unattenuated)
I/O ModulesControl cabinetI/O ModulesField applicationAnalogue modulesOther modulesInductive sensorsPhotoelectric sensorsRotary encodersAccessories 2 mA 1 (attenuated) 4 mASignal delay < 2 ms (input/AS-Interface) Signal frequency 250 Hz
Output
Number/Type 3 relay outputs, normally openSupply none Nominal load Per contact 2 A / 30 V DC; 2 A / 253 V AC Per module 6 AMinimum load Per contact 10 mA / 5 V DCShort-circuit proof Contact: 500 A / 40 ms

Accessories

Switching off power 500 VASwitching delay < 10 ms (AS-Interface/contact)

VBP-HH1

Usage category DC-13 and AC-14Switching frequency f< 20 Hz (without load)< 0.1 Hz (nominal load)

Hand-held programming device VAZ-PK-1,5M-V1-G

Switchings

Connection cable module/hand-held pro-gramming device

Mechanical 30 x 10
6 Electrical 1 x 10
6 (40 V DC, 2 A, ohmic)0.5 x 10
6 (253 V AC, 2 A, cos
6 = 1)0.45 x 10 (253 V AC, 2 A, cos = 0.7)
Electrical isolation
Input/Output IN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1,rated insulation voltage 278 V ACInput/AS-Interface none Output/Output O1 to O2, O3: safe isolation according to EN 60947-1,rated insulation voltage 278 V ACO2 to O3: basic insulation according to EN 60947-1,rated insulation voltage 278 V ACOutput/AS-Interface safe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC
Programming instructions
Profile S-7.A.0 IO code 7ID code A ID1 code 7ID2 code 0 Data bits (function via AS-Interface) inputoutput D0 IN1O1 D1 IN2O2D2 IN3O3 Parameter bits (programmable via AS-i) functionP0 not used P1 not usedP2 not used P3 not used
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 Subject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in German y

Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.co m

131

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 101 p.101
page 102 p.102
page 103 p.103
page 104 p.104
page 105 p.105
page 106 p.106
page 107 p.107
page 108 p.108
page 109 p.109
page 110 p.110
page 111 p.111
page 112 p.112
page 113 p.113
page 114 p.114
page 115 p.115
page 116 p.116
page 117 p.117
page 118 p.118
page 119 p.119
page 120 p.120
page 121 p.121
page 122 p.122
page 123 p.123
page 124 p.124
page 125 p.125
page 126 p.126
page 127 p.127
page 128 p.128
page 129 p.129
page 130 p.130
page 131 p.131
page 132 p.132
page 133 p.133
page 134 p.134
page 135 p.135
page 136 p.136
page 137 p.137
page 138 p.138
page 139 p.139
page 140 p.140
page 141 p.141
page 142 p.142
page 143 p.143
page 144 p.144
page 145 p.145
page 146 p.146
page 147 p.147
page 148 p.148
page 149 p.149
page 150 p.150
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-356
pdf-page pdf di En 2008-12-49-05