AS-Interface - Switch professional cabinet and junction box modules
5.1 Switch cabinet and junction box modules
The KF series, with only a 20 mm widht, provides 4 short-circuit protected inputs, or with a 40 mm width, 4 short-circuit protected inputs and 4 short-circuit protected outputs. A function indicator is available for each channel. The outputs can drive up to 2 A per output and have an external power sup­ply. If no AS-Interface communication occurs, parameter bit P0 can be used to set whether the outputs should then be powered down within 80 ms.
Connection is performed using pluggable coded industrial terminal blocks, guaran­teeing fast and error-free exchanges. The terminals can also be connected under power. The maximum allowable wire size is 2.5 mm2.
The KF modules can simply be popped onto the 35 mm DIN rail (as per EN 50022) in the switch cabinet and connected via Power Rail, so that, for in­stance, only the master in the KF housing must be wired to the AS-Interface flat wire. To do this, either the inset component PR-05 in 0.5 m lengths for the DIN rail is required, or UPR-05 continuous complete rails including DIN rail (2 m lengths, may be cut) can be used.
In the KF housing there is also a data coupler available which can transmit 4 bits of data from one AS-Interface network to a second network.
■a
to >'
2 i
0) q
"co "co
|
to >.
Si "to en
«li
-5 <°
S 2 £> =
= o o
<A.g
°> ro = 2
S to
Alternatively, modules of the KE series can be used in the switch cabinet. In this type, up to 4 inputs and 3 outputs are provided in only 22.5 mm width.
The KE series also features coloured terminal blocks, making connection particularly simple:
yellow: AS-Interface
black: Inputs/Outputs
red: relay outputs.
The Power Rail connection is not supported by the KE series.
2
(A
_a>
T3
o E
0> O)
_o
TO
<
(A _0>
T3
o E
<L>
o
o
(A
0> (A 0> .>
'S
£ jA
0> o
"m CA
O <=
~ <U
O (A
.c
Q.
(A
<D T3 O O
£•
o GC
(A .S!
O (A (A 0> O O <
In decentralised installations, flat junction boxes are often used in order to connect to contacts or sensors. The KE1 series is suitable for this use, with up to 4 inputs and 2 outputs in only 22.5 mm of width and 50 mm of height.
Power supply suppliers is accomplished over the AS-Interface and the KE1 modules are easy to pop onto the DIN rails. The terminals are colour-coded to pre­vent confusion.
The somewhat taller housings of the KE2 series, with two rows of terminals, can be used, for example, with analoguemodules in the switch cabinet.
If 3-wire sensors are attached to a junction box, or power is externally sup­plied, the K3 series is the right solution. In a width of 71 mm and a height of only 40 mm, up to 4 inputs and 3 outputs can be connected. A version with relay output is also available.
Connection is performed by screw terminals (wire size max. 2.5 mm2).
lo
o o
CM
o o
CM
<
Z3 CT) O TO TO O
CT)
s
o
CM
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
108
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 101 p.101
page 102 p.102
page 103 p.103
page 104 p.104
page 105 p.105
page 106 p.106
page 107 p.107
page 108 p.108
page 109 p.109
page 110 p.110
page 111 p.111
page 112 p.112
page 113 p.113
page 114 p.114
page 115 p.115
page 116 p.116
page 117 p.117
page 118 p.118
page 119 p.119
page 120 p.120
page 121 p.121
page 122 p.122
page 123 p.123
page 124 p.124
page 125 p.125
page 126 p.126
page 127 p.127
page 128 p.128
page 129 p.129
page 130 p.130
page 131 p.131
page 132 p.132
page 133 p.133
page 134 p.134
page 135 p.135
page 136 p.136
page 137 p.137
page 138 p.138
page 139 p.139
page 140 p.140
page 141 p.141
page 142 p.142
page 143 p.143
page 144 p.144
page 145 p.145
page 146 p.146
page 147 p.147
page 148 p.148
page 149 p.149
page 150 p.150
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-356
pdf-page pdf di En 2008-12-49-05