Total Station R-2500DN Technical specifications
2Pages

{{requestButtons}}

Catalog excerpts

Total Station R-2500DN Technical specifications - 1

Total Station R-2500DN Technical specifications Model Magnification 30 x Effective aperture 45mm ( EDM45mm ) Resolving power 3.0” Field of view 2.6% ( 1°30’ ) Minimum focus 1.0m Focus Manual Distance measurement Laser Class Visible Laser: Class IIIa ( Reflectorless ) / Class II (Prism, sheet) Measurement range (Good condition) *3 Reflectorless *1 1.5 ~ 600m Reflector sheet *2 1.5 ~ 600m (800m) Mini prism 1.5 ~ 2500m (3000m) 1P 1.5 ~ 7000m(9000m) 3P 1.5 ~ 9000m(9999m) Accuracy *4 Prism / Reflector Sheet 1.5m ~ 10m : ±(3+2ppm x D)mm 10m ~ : ±(2+2ppm x D)mm Reflectorless 1.5m ~ 150m : ±(3+2ppm x D)mm 150m ~ : ±(5+2ppm x D)mm 300m ~ : ±(7+10ppm x D)mm At Auto-ATM. Correction Prism / Reflector sheet 1.5m ~ 10m : ±(3+10ppm x D)mm 10m ~ : ±(2+10ppm x D)mm Reflectorless 1.5m ~ 300m : ±(5+10ppm x D)mm 300m ~ : ±(7+18ppm x D)mm Minimum count 0.1mm (Fine mode) , 1mm (Normal mode) , 10mm (Track mode) Measurement time *5 Repeat meas. Normal(1mm) Prism / Ref.sheet 2.0sec. Ref.less 2.0sec. Quick(1mm) Prism / Ref.sheet 1.2sec. *6 Track(10mm) Prism / Ref.sheet 0.4sec. Ref.less 0.4sec. Initial meas. Normal(1mm) Prism / Ref.sheet 2.5sec. Ref.less 2.4sec. Quick(1mm) Prism / Ref.sheet 1.7sec. *6 Track(10mm) Prism / Ref.sheet 2.5sec. Ref.less 2.5sec. Angle measurement Measuring method Absolute rotary encoder Detection method Vertical / Horizontal angle 2 sides 1 side Minimum count 0.5” / 1” 1” / 5” Accuracy (ISO17123-3) 1” 2” 3” 5” Compensator 3 axis *7 2 axis Tangent Screw 2 Speed 1 Speed Sensitivity of vials Plate level 20”/1div. 30”/1div. 30”/1div. (electronic) (electronic) Circular level 8’/2mm Plummet Visible Laser, ±0.5mm (instrument height 1.5m) or Optical (Optional) Base Detachable Dust and Water Protection IP66 (instrument only) Ambient temperature -20°C ~ 50°C / -4°F ~ 122°F (Working range) Tripod thread 5/8”x 11 Dimensions/Weight Dimensions 190(W) x 343(H) x 177(L)mm Weight (incl. Battery) 5.7kgs. Carrying case 373(W) x 286(H) x 465(L)mm / 2.9kgs. Battery pack BP07 Power source Li-ion 2500mAh x 2 ( hot swap ) Operation time Continuous approx. 4.5 hrs (ETH+EDM), 15 hrs (ETH) with approx. 2.2 hrs of charging time Weight 210g (2) Battery charger BC05 and AC Adapter AC05 Input voltage (AC05) AC 100 ~ 240V Output voltage (BC05) DC8.4V Data Process Data recording method Internal Memory Coordinates data *8 60.000 50.000 Special function PowerTopoLite I/F RS-232C, SD CARD, USB, Bluetooth Display / Keyboard Display type Graphic LCD / 20 characters x 8 lines / 240 x 96 pixels Quantity 2 Keys 22 each(12 numeric / 5 function / 5 special) Display back light Intensity settings: 10 steps Laser Pointer Yes Date clock Yes * Specifications are subject to change without notice *1 The measurement range and accuracy of reflectorless, and time required to measure may vary by the shape, size of surface area and reflection rate of the target and its environment. The measurement range of reflectorless is determined by the white side of the Kodak Gray Card. *2 Reflector sheet: PENTAX genuine Reflector sheet *3 The measurement range may vary by conditions of the environment. Normal conditions: 20km visibility with slight shimmer Good conditions: 40km visibility, overcast, no heat, no shimmer and moderate wind. *4 When automatic atmospheric correction is on, the EDM error is 10ppm in prism and reflector sheet mode. *5 EDM measuring time is determined in good conditions. It may takes longer than usual to measure the distance exceeding 4000m in prism mode and 300m in reflectorless mode. *6 Quick mode, which functions with prism and reflector sheet, is effective only under normal mode(1mm) and up to 500m. *7 In addition to dual-axis correction in the (X) and (Y) direction, mechanical error in the instrument is corrected. *8 Number of points to be recorded may vary by usage. Maximum number of point to be recorded per job site : 3000 points Maximum number of job file to be recorded : 50 job files Maximum data points to be sent from PC to the instrument: 3000 points

Open the catalog to page 1
Total Station R-2500DN Technical specifications - 2

Total Station R-2500DN Technical specifications Digital Camera Sensor Image resolution LCD EV compensation White Blance ISO Sensitivity File format File management Digital zoom Play back function External memory Focus length Focus range Field of view Effective Diameter I/F Power * Designs and specifications are subject to change without notice. - © PENTAX 2013 - SURVEY/04/2013 Data recording method Internal Memory *6 Special function I/F Display / Keyboard Display type Quantity Keys Display back light Laser Pointer Data Clock Internal Memory 45,000 point PowerTopoLite + DSC RS-232C, SD...

Open the catalog to page 2

All PENTAX Precision catalogs and technical brochures

  1. R-200 Series

    2 Pages

  2. W- 800

    4 Pages

  3. R-400VDN

    4 Pages

  4. AFL

    4 Pages

  5. ETH-400

    2 Pages

  6. SMT888-3G

    4 Pages

  7. G3100-R1

    4 Pages

  8. R-400V

    2 Pages

  9. R-400N

    4 Pages

  10. AP

    2 Pages

Archived catalogs

  1. PLP-50H

    2 Pages

  2. PLP-70

    2 Pages

  3. PLP-600

    4 Pages

  4. AP-100

    2 Pages

  5. AFL

    4 Pages

  6. ETH-200

    2 Pages

  7. ETH-300

    2 Pages

  8. DA-20F

    4 Pages

  9. R-100series

    6 Pages

  10. PCS-215,225

    2 Pages

  11. R-100 Trio

    6 Pages

  12. R-300series

    6 Pages

  13. V-200 series

    4 Pages

  14. R-300Xseries

    6 Pages

  15. ATS-series

    4 Pages