Catalogue SSC Sensor Signal Conditioning Module
www.pennyandgiles.com
print switch display
Page / 4
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
PENNY GILES - 14302
/ 4
See other catalogues for PENNY GILES
Text version of the page
10 - 30 unregulated When optional Voltage Module ( VM ) card is fitted, a -10 to -30Vdc negative supply mayalso be connected to increase current sinking capability and reduce noise. If a negative supply is not connected, the VM card automatically generates its ownUnit can operate indefinitely at 33Vdc and is capable of absorbing short duration transients above this10 maximum (plus output currents from 5Vdc source and current output). Additional 9mAwith

SSC

VM card fitted or additional 3mA with PWM card fittedYes - indefinitely 5 ±0.15 (up to 30mA) 1 <±0.01 full stroke 0.5 - 4.5 4 - 20 (and 5 - 19) 0 to 5 & -5 to 0, 0 -10 & -10 to 0, ±2.5, ±5, ±7.5, ±10 TTL level compatible signal with a 10 - 90% duty cycle. User selectable frequencies of 100, 130, 310 and 1000Hz. Logic Signals: LOW <0.4Vdc HIGH 4.5 ±0.5Vdc<5 <10 10k minimum (resistive to 0V line) for nominal 0.5 – 4.5Vdc range onlyOutput current with VM card ranges from 250-750µA (sourcing and sinking) depending on supply voltage. Refer to Penny & Giles where more than 250 µA is requiredVsupply -4V <2<0.001% span<100 (-40 to +70°C) <300 (-40 to +100°C) 0% -75% of range 25% - 100% of range (Turn down = 4) Normal or reversed - jumper selected

SENSOR SIGNAL CONDITIONING MODULE

PERFORMANCEELECTRICAL

Supply voltage VdcOver voltage protection Supply currentmAReverse polarity protectionSensor excitationVdc Sensor output pull down resistorM Ω Linearity (circuit only) % Output signals (jumper selected)VdcmAwith additional VM cardVdc with additional PWM cardOutput noise - voltage range mVrms- current rangeµArmsOutput load (voltage output) Ω Output compliance voltage (current output)Output lag ms Influence of variation in supply voltage on outputTemperature stability ppm/°CZero adjustmentSpan adjustment Output direction Powder coated aluminium alloy250 Bulkhead mounting via M5 fixing holes Via glands – cable diameter must be between 3.0 and 8.0mm diameter to industrial seal to IP68

MECHANICAL

Enclosure Weight g Mounting Cable exit

ENVIRONMENTAL

Operational temperature range°C Protection class EMC immunity levelEN 61000-6-2 -40 to +100 IP68 to 2m for 1 hour duration >100V/m with 1m maximum distance to sensor Normally available from stock

ORDERING CODE

SSC base module with current (4-20 or 5-19mA) or voltage (0.5 - 4.5Vdc) outputs

ACCESSORIESorder separatelyAVAILABILITY

VM additional Voltage Module card to provide extended range of voltage outputs (see specification above) PWM additional Pulse Width Modulation card to provide TTL level signal with 10-90% duty cycle