SRS 880
Ω at 500VdcVoltage divider only - see Circuit Recommendation below
Minimum of 100 x track resistance or 0.5M Ω (whichever is greater) >
PERFORMANCEELECTRICAL
Electrical angle ±2°Resistance ±20% 10 to 350 in 10°increments Ω 14.3 per degree
Less than 0.03
< 1 degree (e.g. ±0.3% over 330°, ±1% over 100°)
0.003 per angular degree
0.2 per angular degree
Virtually infinite
To MIL-R-39023 grade C 0.1%
Greater than 100M Hysteresis (repeatability)°
Accuracy
Power dissipation at 20ËšC W
Applied voltage maximum Vdc Resolution Output smoothness Insulation resistance Operating mode Wiper circuit impedance >
MECHANICAL
Mechanical angle°MountingOperating torque max gm cmShaft velocity max °/sec
Weightg Phasing 360, continuous Use 3 x M6 threaded holes in front face or 3 x M6 clearance holes through the body. See dimensions for details
1000
3000
500
When through hole in shaft (and shaft flat) are 90°from scribed mark on front face, wiper is at
mid travel, ±3° IP68M> 20 million operations (10 x 10 >
ENVIRONMENTAL
Sealing
Shaft seal life Operational temperature°C
Vibration Shock
Explosive atmospheres >
6 cycles) of ±75°-40 to +130 (continuous - sensor only)
RTCA-DO160D, 10Hz to 2000Hz (random), 12.61g rms - all axes
Survival to 2500g - all axes
Classed as ‘simple apparatus’ under BSEN 60079-14:1997 >
CIRCUITRECOMMENDATION
Hybrid track
potentiometers feature a high wiper contact resistance, therefore operational checks
should be carried out only in the voltage divider mode. Hybrid track potentiometers should be
used only as voltage dividers, with a minimum wiper circuit impedance of 100 x track resistance
or 0.5M Ω (whichever is greater). Operation with wiper circuits of lower impedance will degradethe output smoothness and affect the linearity. Can be supplied from 10°to 350°in 10°increments2m or 5m cabled socket assemblies available (rated -25 to +90ºC only)
Operating levers 155 or 230mm. See details on page 7
Available with anodised aluminium or corrosion resistant stainless steel housing
Please contact our sales team for details on our capabilities. >
OPTIONS
Electrical angle
Cabled socket
Operating levers
Body material
Flameproof enclosure >
AVAILABILITY
All configurations can be supplied within ten days from the factory >
6